Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT15910 – Sequences <strong>of</strong> OperationsIssue Date:September 28, 2012Page #:3 <strong>of</strong> 11c. When the controls command space heating on, the lead pumps (P1/P2 and P2.1/P2.2) shall engage.d. P1 and P2 are both constant speed pumps and flow water throughthe boiler room’s loop and the <strong>City</strong> Hall building.3. Time <strong>of</strong> Day Controla. The existing time <strong>of</strong> day controls on heating terminals willcontinue to work as it did before this project began.4. Building Hot Water Control – Normal Conditionsa. The controls shall adjust the speed <strong>of</strong> P2.1/P2.2 to maintain thesetpoint at TT1.4 (main header hot water supply).b. The setpoint at TT1.4 shall follow this adjustable outdoor air resetschedule (linear relation between outdoor air temperature and hotwater temperature:1.) Outdoor air temperature 50 degrees F: Hot watertemperature 140 degrees Fc. Boilers B1 and B2 and their associated pumps shall be <strong>of</strong>f.d. The existing controls (unaffected by this project) for the firedepartment pumps, mixing valve and snowmelt systems shallremain asis. The current operation includes manual engagement <strong>of</strong>the Fire Department heating pump and an inpiping controller forthe Fire Department’s mixing valve. The snowmelt system’scontroller is in the Fire Department basement.e. The controls will position the twoway valve in the district heatsystem to maintain a leaving hot water setpoint <strong>of</strong> 168 degrees F(adjustable).5. Building Hot Water Control – District Heat Failurea. If the controls and district heating system are unable to maintainthe water temperature at TT1.4 with 5 degrees <strong>of</strong> the setpoint formore than 30 minutes or 10 degrees for 5 minutes, the controlsshall signal an alarm at the HMI and engage the lead boiler, boilerpump and shunt pump.b. The system shall stage the boiler between low, high and <strong>of</strong>f tomaintain the setpoint at TT1.4. During this operation the controlsshall keep both boiler pumps engaged continuously.c. During this time, the controls shall keep shutdown the district heatexchanger and pump system and keep the control valve in the loopclosed. This is important to be certain the <strong>City</strong> Hall boilers are notproviding heat to the failed district heating system at the expense<strong>of</strong> <strong>City</strong> Hall.SEQUENCE OF OPERATION159103

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!