Title:16110 – Raceways<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Page #:7 <strong>of</strong> 103.2 INSTALLATION3. Exposed: electrical metallic tubing, unless otherwise noted.4. Concealed: electrical metallic tubing.A. General: Install electrical raceways in accordance with manufacturer's writteninstallation instructions and applicable requirements <strong>of</strong> NEC.B. Conceal Conduit and EMT, unless indicated otherwise, within finished walls,ceilings, and floors. Keep raceways at least 6 inches away from parallel runs <strong>of</strong>flues and steam or hot water pipes. Install raceways level and square and atproper elevations.C. Elevation <strong>of</strong> Raceway: Install horizontal raceway runs above water and steampiping.D. Provide supports for raceways as specified elsewhere in Division 16.E. Prevent foreign matter from entering raceways by using temporary closureprotection.F. Protect stubups from damage where conduits rise from floor slabs. Arrange socurved portion <strong>of</strong> bends is not visible above the finished slab.G. Make bends and <strong>of</strong>fsets so the inside diameter is not effectively reduced. Unlessotherwise indicated, keep the legs <strong>of</strong> a bend in the same plane and the straight legs<strong>of</strong> <strong>of</strong>fsets parallel.H. Run concealed raceways with a minimum <strong>of</strong> bends in the shortest practicaldistance considering the type <strong>of</strong> building construction and obstructions except asotherwise indicated.I. Raceways embedded in slabs: Install in middle third <strong>of</strong> the slab thickness wherepractical and leave at least 1 inch concrete cover. Tie raceways to reinforcingrods or otherwise secure them to prevent sagging or shifting during concreteplacement. Space raceways laterally to prevent voids in the concrete. Runconduit larger than 1inch trade size, parallel with or at right angles to the mainreinforcement; where at right angles to the reinforcement, the conduit shall beclose to one <strong>of</strong> the supports <strong>of</strong> the slab. Where nonmetallic conduit is used,raceways must be converted to rigid steel conduit or electrical metallic tubingbefore rising above floor.RACEWAYS161107

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!