12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Title:15900 – Direct Digital Control SystemPage #:39 <strong>of</strong> 409. Pointtopoint checkout.10. Glossary <strong>of</strong> fully expanded point acronyms.C. Documentation1. Detailed illustrations and complete calibration procedures.2. Complete troubleshooting procedures and guidelines for all systems.3. This material would appear in hardware and s<strong>of</strong>tware manuals previouslydescribed.3.8 TRAINING OF OWNER PERSONNELA. Training Plan: The Contractor shall provide designated Owner personnel training onthe control system in this facility. The intent is to clearly and completely instruct theOwner on all the capabilities <strong>of</strong> the control system. The trainers are expected to be fullyprepared and experienced in training.B. Training I. Control System. The first training shall consist <strong>of</strong> 8 hours <strong>of</strong> actual training.This training may be held onsite. Upon completion, each student, using appropriatedocumentation, should be able to perform elementary operations and describe generalhardware architecture and functionality <strong>of</strong> the system.C. Training II. Building Systems. The second session shall be held onsite for a period <strong>of</strong>12 hours <strong>of</strong> actual handson training after the completion <strong>of</strong> system startup. Thetraining shall be broken into 34 hour sessions held over a period <strong>of</strong> approximately 3weeks (one session per week). When appropriate the session shall include instructionon:1. Specific hardware configuration <strong>of</strong> installed systems in this building and specificinstruction for operating the installed system, including HVAC systems, lightingcontrols and any interface with security and communication systems.2. Security levels, alarms, system startup, shutdown, power outage and restartroutines, changing setpoints and alarms and other typical changed parameters,overrides, freeze protection, manual operation <strong>of</strong> equipment, optional controlstrategies that can be considered, energy savings strategies and set points that ifchanged will adversely affect energy consumption, energy accounting,procedures for obtaining vendor assistance, etc.3. All trending and monitoring features (values, change <strong>of</strong> state, totalization, etc.),including setting up, executing, downloading, viewing both tabular andgraphically and printing trends. Trainees will actually setup trends in thepresence <strong>of</strong> the trainer.4. Every screen shall be completely discussed, allowing time for questions.5. Use <strong>of</strong> keypad or plugin laptop computer at the zone level.6. Use <strong>of</strong> remote access to the system via phone lines or networks.7. Setting up and changing an air terminal unit controller.8. HVAC system overview.9. Operation <strong>of</strong> Control System.10. Function <strong>of</strong> each Component.DIRECT DIGITAL CONTROL SYSTEMS1597239

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!