<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Title:15900 – Direct Digital Control SystemPage #:25 <strong>of</strong> 401.) Setpoint reset slide switch providing an adjustable range.2.) Momentary override request push button for activation <strong>of</strong> afterhours operation.3.) Analog thermometer (exception: where not available for someapplications).3. Duct Mount Sensorsa. Duct mount sensors shall mount in an electrical box through a hole in theduct and be positioned so as to be easily accessible for repair orreplacement.b. Duct sensors shall be insertion type and constructed as a completeassembly including lock nut and mounting plate.c. For outdoor air duct applications, use a weatherpro<strong>of</strong> mounting box withweatherpro<strong>of</strong> cover and gasket.4. Averaging Sensorsa. For ductwork greater in any dimension that 48 inches and/or airtemperature stratification exists, utilize an averaging sensor withmultiple sensing points, when physically possible.b. For plenum applications such as mixed air temperature measurements,utilize a string <strong>of</strong> sensors mounted across the plenum to account forstratification and/or air turbulence. The averaging string shall have aminimum <strong>of</strong> 4 sensing points per 12 foot long segment.c. Provide supports at the sides <strong>of</strong> the duct to support the capillary sensingstring.H. Output Devices General1. Fail Safe Operation:a. Design and install control valves and dampers to fail safe in either thenormally open or normally closed position as required for freeze,moisture, smoke or fire protection.b. Spring Ranges: Provide range as required for system sequencing and toprovide tight close<strong>of</strong>f.1.) Power Operated Control Dampers (other than VAV Boxes):Provide factory fabricated, balanced type dampers.I. Damper Actuators1. Generala. Size operators for smooth and positive operation <strong>of</strong> devices served, andwith sufficient capacity to provide tight shut<strong>of</strong>f against systemtemperatures and pressure encountered. Use rolling diaphragm, pistontype operators with adjustable stops. Equip operators with spring returnfor applications involving fire, freeze protection, moisture protection orspecified normally open/closed operation.DIRECT DIGITAL CONTROL SYSTEMS1597225

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!