12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating15510 – Hydronic Piping<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VTIssue Date:September 28, 2012Page #:13 <strong>of</strong> 14Coordinate with Owner for witnessing the test.3.8 ADJUSTING AND CLEANINGA. Clean and flush hydronic piping systems. Remove, clean, and replace strainerscreens. After cleaning and flushing hydronic piping system, but beforebalancing, remove disposable fine mesh strainers in pump suction diffusers.B. Mark calibrated nameplates <strong>of</strong> pump discharge valves after hydronic systembalancing has been completed, to permanently indicate final balanced position.3.9 INSTALLATION OF WATER TREATMENTA. General: Furnish chemicals recommended by water treatment systemmanufacturer for treating hydronic systems. Provide only chemicals that arecompatible with materials <strong>of</strong> hydronic systems and equipment. Install watertreatment in accordance with chemical treatment manufacturer’s writteninstruction.B. Chemical treatment products specified herein are products <strong>of</strong> <strong>Vermont</strong> BoilerSystems. Provide specified products or products <strong>of</strong> an approved alternatechemical treatment company.C. Hydronic system:1. Provide chemical treatment analysis and findings report <strong>of</strong> the existing hotwater system fluid prior to the new construction work <strong>of</strong> this Project.2. After system has been tested for leaks, and piping systems flushed clean <strong>of</strong>all grit, fillings, dope, etc., add cleaner VBS1960 at the recommendedrate and concentration. Heat to 140 to 180 F and circulate for eight hours.Dump product to drain and flush until pH is +/ 0.3 <strong>of</strong> the raw water.3. After cleaning hydronic system, add passivator VBS1930 and circulate asrecommended by the chemical treatment company.4. After passivating the hydronic system add sufficient corrosion inhibitorVBS1260 to maintain a molybdate level <strong>of</strong> 4060 ppm or asrecommended by chemical treatment company for glycoled hydronicsystems.HYDRONIC PIPING 15510 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!