12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT15140 – Hangers & SupportsIssue Date:September 28, 2012Page #:5 <strong>of</strong> 82. Manufactured Steel Trapezes: Manufactured steel channel shapes <strong>of</strong>dimensions and gauge as required for loads carried per ASTM A570 GR33 and A366 as manufactured by Unistrut or approved equal.3. Trapeze hangers shall be sized for all loads imposed on the trapeze and inaccordance with all applicable codes.4. Where trapeze hangers support fire protection pipes, the trapeze mustconform to the requirements <strong>of</strong> NFPA 13.5. Trapezes for exterior locations must be provided with a galvanized or rustinhibiting acrylic baked enamel finish.G. Install hangers and supports to allow controlled movement <strong>of</strong> piping systems, topermit freedom <strong>of</strong> movement between pipe anchors, and to facilitate action <strong>of</strong>expansion joints, expansion loops, expansion bends and similar units.H. Load Distribution: Install hangers and supports so that piping live and deadloading and stresses from movement will not be transmitted to connectedequipment.I. Pipe Slopes: Install hangers and supports to provide indicated and specified pipeslopes, and so that maximum pipe deflections allowed by ASME B31.9 BuildingServices Piping Code is not exceeded.J. Uninsulated Piping: Provide adjustable clevis hangers, MSS Type1. Providesteel for use with steel piping and copper for use with copper piping. For anyother piping system, provide hangers <strong>of</strong> a compatible material.3.3 INSULATED PIPING REQUIREMENTSA. Supports for steam and condensate return piping 2" and larger and heating hotwater piping 3" and larger shall be provided with a slide support or saddle androller hanger:1. Provide Teflon slide type supports MSS Type 35 or provide protectionsaddles MSS Type 39 with either adjustable roller hangers MSS Type 43or single pipe rolls MSS type 41. Fill interior voids <strong>of</strong> saddles withsegments <strong>of</strong> insulation that match adjoining pipe insulationHANGERS AND SUPPORTS151405

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!