12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT03050 – Concrete and Utility StructuresIssue Date:September 28, 2012Page #:7 <strong>of</strong> 8walls. In lieu <strong>of</strong> an elastomeric sealant, one <strong>of</strong> the following waterpro<strong>of</strong>ingsystems may be installed around all wall penetrations:a. Polyken No. 660 system (Polyken Indistries)b. Bituthene 4000 (Grace Construction Products)c. Jiffy Seal 140/60 (Protecto Wrap)d. Polyguard 650 (Polyguard Products)e. Or approved equal2.4 SLEEVESPART 3Openings for the passage <strong>of</strong> pipes through floors and walls at service entries shall beformed <strong>of</strong> sleeves <strong>of</strong> standardweight, galvanized steel pipe. The sleeves shall be <strong>of</strong>ample diameter to pass the pipe and its insulation, if any, and to permit such expansion asmay occur. Sleeves shall be <strong>of</strong> sufficient length to be flush at the walls and the bottom <strong>of</strong>slabs and to project 2 in. above the finished floor surface. Threaded nipples shall not beused as sleeves.A. Sleeves in exterior walls below ground or in walls below the groundwater levelshall have a 2inch (2”) annular fin <strong>of</strong> 1/8inch (1/8”) plate welded with acontinuous weld completely around the sleeve at about midlength. Sleeves shallbe hot dipped galvanized after the fins are attached.B. All sleeves shall be set accurately before the concrete is placed or shall be built inaccurately as the masonry is being built.C. Schedule 40 steel pipe (minimum wall thickness) shall be used for the followingapplications:1. Exterior Ro<strong>of</strong> and Walls2. Masonry, Stone, and Concrete Walls3. Floor Sleeves (exposed areas)D. Galvanized steel, 22gauge (minimum thickness) sleeves shall be used for thefollowing applications:1. Gypsum wallboard2. Ro<strong>of</strong> and Floors in Concealed Locations and in Chases– EXECUTION3.1 UTILITY STRUCTURE CONSTRUCTION REQUIREMENTSCONCRETE AND UTILITY STRUCTURES030507

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!