12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT16170 – Circuit and Motor DisconnectsIssue Date:September 28, 2012Page #:2 <strong>of</strong> 31. Allen Bradley/Rockwell Automation2. ABB3. CrouseHinds/Cooper Industries4. CutlerHammer/Eaton Corp.5. General Electric Co.6. Siemens Energy & Automation Inc.7. Square D Company2.2 CIRCUIT AND MOTOR DISCONNECT SWITCHESA. General: Provide circuit and motor disconnect switches in types, sizes, duties,features ratings, and enclosures as indicated. Provide NEMA 1 enclosure exceptfor outdoor switches, and other indicated locations provide NEMA 3R enclosureswith raintight hubs. For motor and motor starter disconnects, provide units withhorsepower ratings suitable to the loads.B. Switches shall have quickmake, quickbreak operating mechanism and handlewhich shall be an integral part <strong>of</strong> the box and not the cover. Covers shall havedual interlocks to prevent unauthorized opening <strong>of</strong> the cover with the switch inthe "ON" position or closing <strong>of</strong> the switching mechanism with the cover open.C. Switches shall have switch blades visible in the "OFF" position when the cover isopen. Disconnect switches shall have permanently attached arc suppressorshinged or otherwise attached to permit easy access to the line side lugs withoutremoval <strong>of</strong> the arc suppressors.D. Switches shall have provisions for padlocking in the "OFF" position only, withthree padlock.E. Switch cable lugs shall be U.L. approved for copper and aluminum cables. Allcurrent carrying parts shall be plated by electrolytic process.F. Switch enclosures shall be code gauge steel with rust inhibiting phosphate primerand baked enamel finish.G. Fusible Switches: heavy duty switches, with fuses <strong>of</strong> classes and current ratingsindicated. Where current limiting fuses are indicated, provide switches withnoninterchangeable feature suitable only for current limiting type fuses.H. Nonfusible Disconnects: heavy duty switches <strong>of</strong> classes and current ratings asindicated.CIRCUIT AND MOTOR DISCONNECTS161702

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!