12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT16195 – Electrical IdentificationIssue Date:September 28, 2012Page #:4 <strong>of</strong> 5D. Identify Junction, Pull, and Connection Boxes: Coderequired caution sign forboxes shall be pressuresensitive, self adhesive label indicating system voltage inblack, preprinted on orange background. Install on outside <strong>of</strong> box cover. Alsolabel box covers with identity <strong>of</strong> contained circuits. Use pressuresensitive plasticlabels at exposed locations and similar labels or plasticized card stock tags atconcealed boxes.E. The following fieldapplied colorcoding methods may be used in lieu <strong>of</strong>factorycoded wire for sizes larger than No. 10 AWG.1. Apply colored, pressuresensitive plastic tape in halflapped turns for adistance <strong>of</strong> 6 inches from terminal points and in boxes where splices ortaps are made. Apply the last two laps <strong>of</strong> tape with no tension to preventpossible unwinding. Use 1inchwide tape in colors as specified. Do notobliterate cable identification markings by taping. Tape locations may beadjusted slightly to prevent such obliteration.2. In lieu <strong>of</strong> pressuresensitive tape, colored cable ties may be used for coloridentification. Apply three ties <strong>of</strong> specified color to each wire at eachterminal or splice point starting 3 inches from the terminal and spaced 3inches apart. Apply with a special tool or pliers, tighten for snug fit, andcut <strong>of</strong>f excess length.F. Tag or label conductors as follows:1. Future Connections: Conductors indicated to be for future connection orconnection under another contract with identification indicating sourceand circuit numbers.2. Multiple Circuits: Where multiple branch circuits or control wiring orcommunications/signal conductors are present in the same box orenclosure (except for three circuit, fourwire home runs), label eachconductor or cable. Provide legend indicating source, voltage, circuitnumber, and phase for branch circuit wiring. Phase and voltage <strong>of</strong> branchcircuit wiring may be indicated by mean <strong>of</strong> coded color <strong>of</strong> conductorinsulation. For control and communications/signal wiring, use colorcoding or wire/cable marking tape at terminations and at intermediatelocations where conductors appear in wiring boxes, troughs, and controlcabinets. Use consistent letter/number conductor designations throughouton wire/cable marking tapes.3. Match identification markings with designations used in panelboards shopdrawings, Contract Documents, and similar previously establishedidentification schemes for the facility's electrical installations.ELECTRICAL IDENTIFICATION161954

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!