12.07.2015 Views

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

Specifications - City of Montpelier, Vermont

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Title:<strong>Montpelier</strong> District Heating<strong>City</strong> <strong>of</strong> <strong>Montpelier</strong>, VT15891 – Metal Ductwork & AccessoriesIssue Date:September 28, 2012Page #:5 <strong>of</strong> 19D. Duct Sealant, Two Part System: Twopart system consisting <strong>of</strong> an adhesiveactivator and a gypsum impregnated fiber tape. Materials shall be suitable for useoutdoors, and shall be listed by UL Laboratories to have a flame spread andsmoke developed ratings <strong>of</strong> less than 25, wet <strong>of</strong> dry.1. Hardcast: DT5300 tape and RTA50 adhesive2. United McGill: UnicastE. Duct Sealant, Flange Type: Continuous butyl rubber extrusion specificallydesigned for use in flanged duct joints. Product shall be listed by ULLaboratories to have a flame spread and smoke developed ratings <strong>of</strong> less than 25,wet <strong>of</strong> dry.1. Hardcast: Flange Grip #1902FRF. Ductwork Support Materials: Except as otherwise indicated, provide hotdippedgalvanized steel fasteners, anchors, rods, straps, trim and angles for support <strong>of</strong>ductwork.1. For stainless steel, aluminum or copper ductwork, provide supportmaterials compatible with the materials being supported.2.3 RECTANGULAR DUCT FABRICATIONA. General: Except as otherwise indicated, fabricate rectangular ducts withgalvanized sheet steel, in accordance with SMACNA “HVAC Duct ConstructionStandards, Third Edition (2005)” Tables 21 through 249, including associateddetails. Fabricate rectangular ducts with aluminum sheet, in accordance withSMACNA “HVAC Duct Construction Standards, Third Edition (2005) Tables 21through 252, including associated details. Conform to the requirements in thereferenced standard for metal thickness, reinforcing types and intervals, tie rodapplications, and joint types and intervals.B. Fabricate rectangular ducts in lengths appropriate to reinforcement and rigidityclass required for pressure classification.C. Provide materials that are free from visual imperfections such as pitting, seammarks, roller marks, stains, and discoloration.D. Cross Breaking or Cross Beading: Cross break or bead duct sides that are 11" andMETAL DUCTWORK AND ACCESSORIES 15891 5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!