Drive modules<br />

3.<br />

DRIVE MODULES<br />

Modular drives<br />

188<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

124<br />

MMC 3.200/3.250<br />

These drive modules have the following connectors:<br />

X5<br />

X3<br />

X4<br />

X3<br />

U V W<br />

X6<br />

SL2 SL1<br />

1<br />

POSITIONING DRIVE<br />

STATUS<br />

DISPLAY<br />

AS1<br />

AS2<br />

GND<br />

DRIVE<br />

ENABLE<br />

SPEED<br />

ENABLE<br />

DR.<br />

O.K.<br />

0 V<br />

+24 Vdc<br />

DANGER<br />

HIGH VOLTAGE<br />

DISCHARGE TIME > 4 Min<br />

U V W<br />

IVE<br />

X1<br />

X7<br />

X2<br />

RESET button<br />

Warning. AC touch current greater than 3.5<br />

mA. Install a ground wire with a section of at<br />

least 10 mm² Cu or 16 mm² Al.<br />

(a) NODE (b) NODE (c)<br />

4 SELECT 4 SELECT 4<br />

SERCOS CAN<br />

RS422<br />

F. H3/58<br />

Connectors of “MMC 3.200/3.250” modular drives.<br />

1. Power connector for motor connection.<br />

2. Power bus that feeds the drive modules from the power supply through metal plates.<br />

X1. Connector that may be used to establish communication between modules through the internal bus.<br />

X2. Connector for the basic control signals.<br />

X3. Connector with two possible uses:<br />

• as output of the encoder simulator.<br />

• as input of the direct feedback for the position loop.<br />

X4. Connector for motor feedback connection (encoder).<br />

X5. Connector for RS-232 serial line connection.<br />

X6. Possible connectors that may be located in this position:<br />

• SERCOS a or CAN b interface connector (always with X5)<br />

• Connector for RS-232/RS-422 c serial line connection (never with X5)<br />

X7. Connector for external acknowledgment of the status of the safety relay.<br />

SL1.Slot for the cards A1, 16DI-8DO and 8DI-16DO.<br />

SL2.Slot for the cards 16DI-8DO and 8DI-16DO.<br />

0<br />

X3<br />

X4<br />

Possibilities:<br />

X5.Serial line RS-232 + <br />

OR X6.Serial line RS-232/RS-422 c - without X5 -<br />

8<br />

0<br />

8<br />

AS1<br />

AS2<br />

BOOT button.<br />

Software update and SER-<br />

COS/CAN.Transmission<br />

speed selection.<br />

X5<br />

GND<br />

DRIVE<br />

ENABLE<br />

SPEED<br />

ENABLE<br />

DR.<br />

O.K.<br />

0V<br />

+24Vdc<br />

0<br />

2<br />

X7<br />

X2<br />

NODE<br />

SELECT<br />

8<br />

OUT<br />

5<br />

4<br />

3<br />

1<br />

X6<br />

2<br />

1<br />

X6<br />

9<br />

X6<br />

IN<br />

0<br />

1<br />

X1