28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

7.2 Power cable. Motor-drive connection<br />

i<br />

Table T. H7/4 and table T. H7/5 show the range of power cables supplied<br />

by FAGOR to connect a motor and a drive. They are supplied without<br />

connectors because the power connector will usually be different depending<br />

on the motor it will be connected to. The number of meters available<br />

upon request. It is available in lengths of 5, 10, 15, 20, 30, 40, 50,<br />

75, 100, 150, 200, 250 and 300 meters for sections up to 10 mm² (included)<br />

and 5, 7, 10, 12, 15, 20, 25, 30, 35, 40, 45, 50, 75 and 100 for sections<br />

of up to 50 mm 2 (included). Their sales reference is:<br />

MPC-4x<br />

to connect motors without brake<br />

MPC-4x+(2x) to connect motors with brake<br />

T. H7/4 Range of cables to connect a motor (without brake) and a drive.<br />

MPC-4x1.5 MPC-4x4 MPC-4x10 MPC-4x25 MPC-4x50<br />

MPC-4x2.5 MPC-4x6 MPC-4x16 MPC-4x35 MPC-4x70<br />

T. H7/5 Range of cables to connect a motor (with brake) and a drive.<br />

MPC-4x1.5+(2x1) MPC-4x6+(2x1) MPC-4x25+(2x1)<br />

MPC-4x2.5+(2x1) MPC-4x10+(2x1)<br />

MPC-4x4+(2x1) MPC-4x16+(2x1.5)<br />

INFORMATION. Remember that when a motor is mentioned here, it refers<br />

to any motor of the FAGOR catalog, both synchronous and asynchronous.<br />

MANDATORY. In order for the system to comply with the European Directive<br />

on Electromagnetic Compatibility, the cable hose that carries 6 or<br />

4 cables, depending on whether the motor has a brake or not, must be<br />

shielded and connected at both ends; i.e. both at the drive end and a the<br />

motor end. This condition is a must.<br />

Power terminals. Mechanical characteristics<br />

The mechanical characteristics of the terminals (U, V, W, PE) on modular<br />

drives are:<br />

T. H7/6 Mechanical characteristics of the power connectors of the modular<br />

drives.<br />

Module Gap<br />

(mm)<br />

Max. tightenin<br />

torque<br />

(N·m)<br />

Max. hole<br />

section<br />

(mm²)<br />

Min. cable<br />

section<br />

(mm²)<br />

AXD/SPD/MMC 1.08/1.15 7.62 0.6 4 2.5<br />

AXD/SPD/MMC 1.25 7.62 0.8 6 6<br />

AXD/SPD/MMC 1.35 10.16 1.5 6 6<br />

AXD/SPD/MMC 2. 10.16 1.8 16 16<br />

SPD 2.85 10.16 1.8 16 16<br />

AXD/SPD/MMC 3.100 - 8 50 25<br />

AXD/SPD/MMC 3.150 - 8 50 50<br />

SPD 3.200 - 20 95 70<br />

SPD 3.250 - 20 95 95<br />

MANDATORY. The cable wires connected at the motor end must be kept<br />

inside their corresponding connector. The connector will be different depending<br />

on the user's motor.<br />

For further details on the connector that must be mounted at the end of<br />

the MPC cable and connected at the motor end, see the manual of the<br />

corresponding motor.<br />

Cables<br />

CABLES<br />

Power cable. Motor-drive connection 7.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

249