Drive modules<br />

3.<br />

DRIVE MODULES<br />

Compact drives<br />

188<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

152<br />

Drives for a synchronous or asynchronous motor working as a spindle<br />

The following graphs show the maximum rms current in continuous duty<br />

cycle (that is, the rated one) depending on the switching frequency of the<br />

power transistors that the drive modules for asynchronous motors can<br />

supply in a temperature range between 5 °C (41 °F) and 60 °C (140 °F).<br />

For a switching frequency fc = 4 kHz<br />

11<br />

10<br />

9<br />

8<br />

I (Arms)<br />

F. H3/98<br />

Current derating on “SCD 1.15” drives for fc = 4 kHz.<br />

18<br />

17<br />

16<br />

15<br />

F. H3/99<br />

Current derating on “SCD 1.25” drives for fc = 4 kHz.<br />

28<br />

26<br />

24<br />

22<br />

F. H3/100<br />

Current derating on “SCD 2.35” drives for fc = 4 kHz.<br />

F. H3/101<br />

Imax<br />

Tambient<br />

°C (°F)<br />

35 40 45 50 55 60<br />

(95) (104) (113) (122) (131) (140)<br />

I (Arms)<br />

Imax<br />

35 40 45 50 55 60<br />

(95) (104) (113) (122) (131) (140)<br />

I (Arms)<br />

Imax<br />

Tambient<br />

°C (°F)<br />

Tambient<br />

°C (°F)<br />

35 40 45 50 55 60<br />

(95) (104) (113) (122) (131) (140)<br />

I (Arms)<br />

40<br />

30<br />

20<br />

10<br />

Imax<br />

Tambient<br />

°C (°F)<br />

35 40 45 50 55 60<br />

(95) (104) (113) (122) (131) (140)<br />

Current derating on “SCD 2.50” drives for fc = 4 kHz.<br />

SCD 1.15<br />

Tª ambient Imax.<br />

°C °F Arms<br />

35 95 10.6<br />

40 104 10.6<br />

45 113 10.6<br />

50 122 9.9<br />

55 131 9.1<br />

60 140 8.2<br />

SCD 1.25<br />

Tª ambient Imax.<br />

°C °F Arms<br />

35 95 17.5<br />

40 104 17.5<br />

45 113 17.5<br />

50 122 16.8<br />

55 131 15.9<br />

60 140 14.9<br />

SCD 2.35<br />

Tª ambient Imax.<br />

°C °F Arms<br />

35 95 28.0<br />

40 104 28.0<br />

45 113 28.0<br />

50 122 27.2<br />

55 131 24.5<br />

60 140 22.7<br />

SCD 2.50<br />

Tª ambient Imax.<br />

°C °F Arms<br />

35 95 38.0<br />

40 104 38.0<br />

45 113 38.0<br />

50 122 36.3<br />

55 131 34.3<br />

60 140 32.2