Ohm value<br />

WARNING. When connecting an external braking resistor other than the<br />

one shown in table T. H4/8 make sure that its Ohm value is the same as<br />

that of the internal Ballast resistor of the unit. Verify it in the technical<br />

characteristics table of the corresponding power supply in chapter 2 or of<br />

the corresponding compact drive in chapter 3 of this manual.<br />

ACD/CMC/SCD compact units without NR reference have a particular resistor<br />

associated with them; FAGOR supplies it in an accessory bag inside<br />

the unit package and the user must install it. This is not the case for units<br />

with NR reference for which the user must select the appropriate resistor<br />

model depending on the energy to be dissipated in the application. Therefore,<br />

the latter do not come with the resistor in the accessory bag of the unit<br />

and it must be requested separately.<br />

Use the attached table to select the external Ballast resistor for your power<br />

supply with enough rms power to dissipate the energy generated while<br />

braking.<br />

T. H4/8 Possible braking resistors to be installed on power supplies.<br />

Required Ohm values.<br />

PS-25B4 18 <br />

XPS-25 18 <br />

PS-65A 9 <br />

XPS-65 9 <br />

950 W ER+TH-18/1100<br />

1.3 kW ER+TH-18/1800<br />

2.0 kW ER+TH-18/2200<br />

2.0 kW ER+TH-18/1000+FAN<br />

3.0 kW ER+TH-18/1500+FAN<br />

4.0 kW ER+TH-18/2000+FAN<br />

950 W ER+TH-18/1100<br />

1.3 kW ER+TH-18/1800<br />

2.0 kW ER+TH-18/2200<br />

2.0 kW ER+TH-18/1000+FAN<br />

3.0 kW ER+TH-18/1500+FAN<br />

4.0 kW ER+TH-18/2000+FAN<br />

1.9 kW 2x ER+TH-18/1100 in parallel<br />

2.6 kW 2x ER+TH-18/1800 in parallel<br />

4.0 kW 2x ER+TH-18/2200 in parallel<br />

4.0 kW 2x ER+TH-18/1000+FAN in parallel<br />

6.0 kW 2x ER+TH-18/1500+FAN in parallel<br />

8.0 kW 2x ER+TH-18/2000+FAN in parallel<br />

1.9 kW 2x ER+TH-18/1100 in parallel<br />

2.6 kW 2x ER+TH-18/1800 in parallel<br />

4.0 kW E2x R+TH-18/2200 in parallel<br />

4.0 kW 2x ER+TH-18/1000+FAN in parallel<br />

6.0 kW 2x ER+TH-18/1500+FAN in parallel<br />

8.0 kW 2x ER+TH-18/2000+FAN in parallel<br />

Auxiliary modules<br />

AUXILIARY MODULES<br />

External Ballast resistors 4.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />