How to install two external Ballast resistor in parallel. Diagrams<br />

Always install both resistors vertically<br />

Diagram for two resistors in parallel with fan and internal thermostat<br />

A una toma<br />

50/60 Hz<br />

220/240 V AC<br />

del armario<br />

Re L+<br />

Re L+<br />

Axial fan<br />

Internal<br />

thermostat<br />

Take the connection terminals of each fan<br />

to an outlet of the electrical cabinet, single<br />

phase 50/60 Hz, 220/240 V AC. Consumption:<br />

0.15/0.13 A, 23/20 W.<br />

Internal<br />

thermostat<br />

160°C<br />

160°C<br />

+ 24 V DC<br />

+ 24 V DC<br />

PLC INPUT<br />

Re L+<br />

Take the terminal labeled + 24 V DC to an external 24<br />

V DC power supply of the electrical cabinet and the<br />

other one labeled PLC INPUT to a PLC input. Important.<br />

Remember to manage the chosen PLC input in<br />

the PLC program to generate an error when exceeding<br />

the limit temperature (160 °C) detected by the sensor<br />

and to open the contact.<br />

PLC INPUT<br />

Re L+<br />

Internal<br />

thermostat<br />

F. H8/17<br />

Installing two external Ballast resistors in parallel.<br />

Axial fan<br />

160°C<br />

L+<br />

Internal<br />

thermostat<br />

160°C<br />

L+<br />

Re<br />

Re<br />

A una toma<br />

50/60 Hz<br />

220/240 V AC<br />

del armario<br />

Take the indicated terminals to the Re and<br />

L+ terminals of the terminal strip of the<br />

Ballast of the power supply (only PS-65A<br />

or XPS-65).<br />

Diagram for two resistors in parallel with an internal thermostat and no fan<br />

Take the terminal labeled + 24 V DC to an external 24<br />

V DC power supply of the electrical cabinet and the<br />

other one labeled PLC INPUT to a PLC input. Important.<br />

Remember to manage the chosen PLC input in<br />

the PLC program to generate an error when exceeding<br />

the limit temperature (160 °C) detected by the sensor<br />

and to open the contact.<br />

Take the indicated terminals to the Re and<br />

L+ terminals of the terminal strip of the<br />

Ballast of the power supply (only PS-65A<br />

or XPS-65).