Terminal strip to connect the Ballast resistor<br />

Regenerative power supplies also have a small Ballast Circuit for dissipating<br />

energy in case of an emergency. This emergency is issued when<br />

there is no connection to mains and the Ballast circuit activating voltage is<br />

exceeded. See table T. H2/14 in this chapter. Here are the two possible<br />

configurations:<br />

F. H2/20<br />

Ballast resistor connection configurations.<br />

Removing this jumper between Ri and L+ (factory setting) and not connecting<br />

an external resistor between Re and L+ generates error code E215 or<br />

E304 on the display.<br />

The following table shows the values for gap, tightening torque, sections<br />

and other interesting data of the feed-through terminals blocks for connecting<br />

the ballast resistor:<br />

T. H2/17 Technical data of the feed-through terminal blocks for connecting<br />

the ballast resistor.<br />

Connector data XPS-25 XPS-65<br />

Min/max tightening torque (N·m) 0.6/0.8 0.6/0.8<br />

Screw thread M3 M3<br />

Min./max. section (mm²) 0.2/4 0.2/4<br />

Rated current In (A) 32 32<br />

These power supplies carry a protection against over-temperature which<br />

triggers error E301 on the display when reaching 105 °C (221 °F).<br />

Derating curves<br />

The power that may be dissipated through the internal ballast resistor located<br />

inside the power supply XPS-25 depends on the ambient temperature<br />

as determined by the derating curve.<br />

600<br />

520<br />

Configuration of the<br />

internal resistor<br />

XPS-25<br />

XPS-65<br />

R.int<br />

L-<br />

CONTROL<br />

INTERNAL BALLAST<br />

POWER (W)<br />

L+<br />

F. H2/21<br />

Derating curve of regenerative power supplies XPS-25.<br />

Configuration of the<br />

external resistor<br />

Ri Re L+ Ri Re L+<br />

XPS-25<br />

°C/°F<br />

35/95 45/113<br />

R.ext<br />

ER+TH-X/X<br />

ER+TH-18/X+FAN<br />

XPS-25<br />

XPS-65<br />

R.int<br />

The performance of the internal Ballast resistor of the regenerative power<br />

supply XPS-65 does not suffer at high temperatures.<br />

L-<br />

CONTROL<br />

Power supplies<br />

L+<br />

POWER SUPPLIES<br />

Regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />