Installation<br />

8.<br />

INSTALLATION<br />

Connection of the control and communications signals<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

308<br />

RS-422 serial line connection<br />

NOTE. This communication interface may be set only between drive modules<br />

MMC or CMC and an ESA video terminal as a master element.<br />

The various drive modules and the ESA panel are connected through the<br />

RS-232/422 serial port (connector X6) of the drive and the serial port of the<br />

video terminal (connector MSP).<br />

The RS-232/422 serial port is implemented only on FAGOR drives in<br />

motion control applications (see their front panel).<br />

The connection is made through the RS-232/422 cable.<br />

See chapter 7. CABLES of this manual.<br />

It is a tree type connection where the 16-position rotary switch (0-15) of<br />

each drive permits selecting the address of each module integrated in it.<br />

NOTE. The system communication through RS-232/422 is configured using<br />

the WinDDSSetup application for PC. See the “communications” tab<br />

of the menu in chapter 16. WINDDSSETUP of the “ddssoftware”<br />

manual.<br />

Particular<br />

In order to establish communication via RS-232 serial line, each drive of the<br />

system must be differentiated using the 16-position “NODE SELECT”<br />

switch. The direction of the arrow of the switch must coincide with an identifier<br />

other than zero, hence assigning a node number that will identify in the<br />

system.<br />

If the drive is going to be identified in the SERCOS ring with a number higher<br />

than 15 in a tree-like structure that has RS-422 communications line, this<br />

value cannot be selected using the rotary “NODE SELECT” switch because<br />

it only has 15 positions.<br />

Identifying the axes with addresses higher than 15 requires setting QP13.<br />

See this parameter in chapter 13 of the “dds-software” manual.<br />

Example.<br />

How to identify an axis addressed in position 26 in the system when communicating<br />

via RS-422 serial line ?<br />

When the identifier of the axis is higher than 15 (like in this case), QP13<br />

must be set so it meets the ratio:<br />

Defined ID = ID to be selected at the rotary switch + (15 x QP13).<br />

Hence, for defined ID = 26, select C (same as 11) at the drive's rotary<br />

“NODE SELECT” switch and set QP13=1.<br />

In order to establish communication via RS-232 serial line, the direction of<br />

the arrow of the switch of the corresponding module must coincide with the<br />

zero identifier.<br />

NOTE. The module must be reset in order for any change made on the<br />

rotary switch to be effective.<br />

Interconnection<br />

Use the RS-232/422 cable to connect all the drives that will be governed by<br />

the video terminal. See chapter 7. CABLES of this manual.