Dip-Switches (DS1, DS2)<br />

DS1<br />

DS2<br />

F. H3/78<br />

Factory settings of the dip-switches (DS1, DS2).<br />

Adjustment outputs With these outputs and a potentiometer, the user can obtain a variable analog<br />

voltage for adjusting the servo system during setup.<br />

The voltage, with no load, at these pins is ±15 V DC.<br />

The electrical circuit necessary to obtain a reference voltage and the recommended<br />

resistance values to obtain an approximate range of ±10 V<br />

DC for the Vref are described next:<br />

1<br />

X7-ANALOG I/Os X6-DIGITAL I/Os<br />

1<br />

P2<br />

P1<br />

A1<br />

MANDATORY. The status of the dip-switches (DS1, DS2) must not be<br />

changed by the operator.<br />

Vref<br />

Rext<br />

F. H3/79<br />

Adjustment outputs.<br />

R'<br />

R'<br />

GND<br />

Range ±10 V<br />

Rext. R’<br />

1 k 0 <br />

5 k 820 <br />

10 k 1.8 k<br />

20 k 3.3 k<br />

X7<br />

1<br />

4<br />

5<br />

DRIVE<br />

6 -15 V DC<br />

7 +15 V DC<br />

8<br />

10<br />

Drive modules<br />

DRIVE MODULES<br />

Modular drives 3.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />