Installation<br />

8.<br />

INSTALLATION<br />

Connection of the control and communications signals<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

294<br />

Connection for the digital outputs<br />

When the drive outputs are connected to inductive loads, we must protect<br />

the optocoupler with circuits such as the ones shown in the next figure:<br />

DC<br />

R ~1 <br />

C<br />

0.1-1mF 250V<br />

AC/DC<br />

1N4000<br />

Vbr=2.4 V DC<br />

IF=Load<br />

(1 )<br />

AC/DC<br />

R ~1 <br />

C<br />

0.1-1mF 250V<br />

F. H8/23<br />

Protection circuits for the opto-coupler of the digital output with inductive<br />

loads.<br />

LOAD LOAD LOAD