Installation<br />

8.<br />

INSTALLATION<br />

Connection of the control and communications signals<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

298<br />

Transmission speed changing procedure<br />

In an initial state (0 state), the display shows the information that already<br />

showed in previous versions (errors, SERCOS phase, etc.). Keeping the<br />

“boot” button pressed for 3 seconds (long push) it switches to a new state<br />

(state 1) that is used for selecting the communication speed and the display<br />

shows the speed currently selected.<br />

In this state 1, every time this button is pressed for less than 0.8 seconds<br />

(short push), the display shows the next communication speed value that<br />

may be selected.<br />

Hence, apply several short pushes until the desired speed is displayed.<br />

Once the display shows the desired speed, apply a long push and QP11<br />

will be assigned its associated value that will be saved into the flash memory<br />

of the drive and will reset the drive.<br />

no no<br />

no<br />

Pressed<br />

t < 0.8 s<br />

yes<br />

Next rate<br />

Error message<br />

Button OFF<br />

yes<br />

F. H8/28<br />

Diagram of the SERCOS transmission speed selecting procedure.<br />

Anomalous events during the procedure<br />

no<br />

Start<br />

Normal Display<br />

Button ON<br />

t > 3 s<br />

yes<br />

Show the transmission<br />

rate on the display<br />

Button ON<br />

t > 3 s<br />

Any error that comes up when saving parameters into flash memory, will be<br />

displayed with an error message on the display while the “boot” button is<br />

pressed and then it will return to state 1 (speed selection).<br />

NOTE. Any attempt to select a value other than those assigned to the<br />

possible transmission speeds will generate an error and it will not be selected.<br />

Any change of the communication speed is maintained after the drive is<br />

turned off if the command to save parameters has been previously executed<br />

successfully.<br />

If, for any reason, the drive is turned off or reset in any stage of this procedure,<br />

when started up again, the transmission speed value given by QP11<br />

will be the last one that was successfully assigned in previous changes.<br />

The speed change procedure may be ignored (without making any changes)<br />

at any time if the command to save parameters has not been executed.<br />

NOTE. While in state 1, after 8 seconds without pressing the “boot” button,<br />

the drive switches to 0 state and the display shows the initial information.<br />

yes<br />

Save parameters<br />

Saved<br />

Ok<br />

yes<br />

Drive Reset<br />

End<br />

no<br />

Button OFF<br />

t > 3 s<br />

yes<br />

Normal display<br />

End<br />

no