13.6 VECON-3 board<br />

13.7 VECON-4 board<br />

13.8 Boot for VECON-2<br />

13.9 Boot for VECON-3<br />

13.10 Boot for VECON-4<br />

13.11 SERCOS card (16 MBd)<br />

i<br />

This board replaces the VECON-2 board.<br />

Version of the VECON-3 board Software version<br />

VEC 01A and later 06.18 and later<br />

NOTE. It is possible but not recommended to have the same machine<br />

with several units where one controls its motor with a 04.xx version and<br />

hardware with VECON another one that controls its motor with a 05.xx<br />

version and hardware with VECON-2 and a third one that controls its motor<br />

with 06.18 version or later and VECON-3 hardware.<br />

This board replaces the VECON-3 board.<br />

Versión of the VECON-4 board Software version<br />

VEC 01A and later 06.26 and later<br />

08.05 and later<br />

NOTE. It is possible but not recommended to have the same machine<br />

with several units where one controls its motor with a 05.xx version and<br />

hardware with VECON-2 another one that controls its motor with a<br />

06.18 version and hardware VECON-3 and a third one that controls its<br />

motor with 08.05 version and hardware VECON-4 hardware.<br />

The boot of version v.06.02 and later of the WinDDSSetup allow loading<br />

the software versions on VECON-2 boards (version VEC2 02A).<br />

NOTE. The boot of previous WinDDSSetup versions is incompatible with<br />

board versions VEC2 02A.<br />

The boot of version 06.18 and older of the WinDDSSetup allow loading<br />

the software versions on VECON-3 boards (version VEC3 01A).<br />

NOTE. The boot of previous WinDDSSetup versions is incompatible with<br />

board versions VEC3 01A.<br />

The boot of versions 06.26 and 08.05 and older of the WinDDSSetup allow<br />

loading the software versions on VECON-4 boards (versión VEC4<br />

01A).<br />

NOTE. The boot of previous WinDDSSetup versions is incompatible with<br />

board versions VEC4 01A.<br />

This card will not be compatible with software versions older than 06.05.<br />

With software versions 06.05 and later, this new board may be used to exchange<br />

data between the CNC and the drives that make up the SERCOS<br />

ring at 2, 4, 8 and 16 MBd.<br />

NOTE. Therefore, in order to select a baudrate higher than 4 Mbaud, the<br />

drive must have this SERCOS board and software version v.06.05 or newer.<br />

INFORMATION. Drives having this board or older ones may be added to<br />

the SERCOS ring. However, all the drives must set with the same transmission<br />

speed.<br />

Compatibility<br />

COMPATIBILITY<br />

VECON-3 board 13.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

381