Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

92<br />

Regenerative regulated power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

Operating modes<br />

See the next running status diagram:<br />

F. H2/53<br />

Running state diagram of the RPS power supply.<br />

Running states<br />

Description of the possible running states:<br />

Status Meaning<br />

0 Without power line connection. Stand by.<br />

1 Loading the DC BUS. Temporary state.<br />

2 Running in BOOST mode.<br />

The system works like a BOOST power supply.<br />

3 Running in REGENERATOR mode. The system works as a generator<br />

discharging the excess energy of the DC BUS into mains.<br />

4 Emergency state.<br />

Transitions between running states<br />

The transitions between states are done automatically and the system<br />

adapts itself to the relevant operating mode depending on the mains voltage<br />

and on the DC BUS voltage. These transitions are:<br />

Transition Meaning<br />

A The power line connection is made.<br />

B<br />

C<br />

D<br />

STATE 0<br />

WITHOUT POWER<br />

A B<br />

STATE 1<br />

LOADING DC BUS<br />

C<br />

STATE 2<br />

BOOST MODE<br />

D E<br />

STATE 3<br />

GENERATOR MODE<br />

STATE 4<br />

EMERGENCY STOP<br />

F<br />

The time set as the minimum time limit (3.2 s) to charge<br />

the DC BUS has been exceeded. The charge process has<br />

failed and error E315 of the DC BUS comes up. Temporary<br />

state.<br />

The charge process has finished correctly.<br />

The line voltage is within the levels set to consider it<br />

working in boost mode (323424 V AC). The DC BUS<br />

voltage is lower than 625 V DC.<br />

The BUS voltage is higher than the nominal voltage set<br />

for the DC BUS and the value of the mains voltage is<br />

within the limits set to work in generator mode.<br />

The BUS voltage is lower than the nominal voltage set for<br />

E<br />

the DC BUS and the value of the mains voltage is within<br />

the limits set to work in boost mode.<br />

F The emergency stop has ended.