NOTE. When detecting an error, it will switch from any state 0, 1, 2 or 3<br />

directly to state 4. From any of the states, it will switch to state 0 if a<br />

stop occurs due to the NO READY state of any of the drives connected<br />

to the power supply or because the power line has been disconnected<br />

or because the emergency stop button has been pressed or because<br />

the line voltage has dropped.<br />

Follow this sequence to stop the system without having detected any errors:<br />

Disabling the drives; i.e. disable the Speed Enable of all the axes or the<br />

System Speed Enable.<br />

Disconnecting the power line by opening the contactor - KM1, usually<br />

by pressing the E-STOP button.<br />

Power supplies<br />

POWER SUPPLIES<br />

Regenerative regulated power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />