Installation<br />

8.<br />

INSTALLATION<br />

Location<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

268<br />

MANDATORY. When integrating the unit into the electrical cabinet, make<br />

sure to leave a gap of at least 10 cm (3.93 inches) between it and the top,<br />

bottom and front panel of the cabinet or any other obstacle that obstructs<br />

air flow for easier heat evacuation.<br />

For further detail, see next figure:<br />

AIR<br />

F. H8/1<br />

Top and bottom clearance when installing the DDS system for easier heat<br />

evacuation.<br />

Climatic considerations<br />

AIR<br />

MANDATORY. Mount the modular drive of greatest power next to the<br />

power supply module and use the same criteria for the rest of the drive<br />

modules.<br />

The temperature inside the electrical cabinet containing the servo drive<br />

system must not exceed 55 °C (131 °F).<br />

MANDATORY. Never install the DDS system next to a heat source.<br />

The modules generate heat and when trying to decide whether the electrical<br />

cabinet containing the DDS system needs external cooling or not, one<br />

must know the power dissipated by each one of its modules.<br />

See next table to know the power dissipated by each one of them.<br />

T. H8/1 Power dissipated by the modules of the DDS system.<br />

Power supply module Power dissipated at max. load.<br />

PS-65A 275 W<br />

PS-25B4 180 W<br />

XPS-25 180 W<br />

XPS-65 350 W<br />

RPS-80 1 000 W<br />

RPS-75 1 000 W<br />

RPS-45 700 W<br />

RPS-20 500 W