Drive modules<br />

3.<br />

DRIVE MODULES<br />

Compact drives<br />

188<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

148<br />

Load duty cycles<br />

Load cycle S1 with current peak<br />

Ip<br />

IN<br />

I<br />

F. H3/85<br />

Load cycle S1 with current peak.<br />

Load cycle S6<br />

IMAX<br />

IS6-40<br />

IN<br />

0.7 x IN<br />

F. H3/86<br />

Load cycle S6-40.<br />

Load cycle S6 with current peak<br />

IMAX<br />

IS6-40<br />

IN<br />

0.7 x IN<br />

F. H3/87<br />

Load cycle S6 with current peak.<br />

Definition of currents<br />

On axes:<br />

I<br />

I<br />

In “Continuous duty cycle” current.<br />

Ip Peak current.<br />

See load duty cycles.<br />

On spindles:<br />

0.5 s<br />

10 s<br />

10 min<br />

10 s<br />

60 s<br />

4 min<br />

In “Continuous duty cycle” current.<br />

IS6-40% Current that, in an intermittent duty cycle S6 with 10 minute<br />

cycle, circulates for 4 minutes with load (the other 6 minutes operates<br />

without load); in other words with magnetizing current = 0.7 x<br />

rated current In).<br />

Imax Maximum peak current.<br />

See load duty cycles.<br />

Note. The values of these currents are given in RMS.<br />

S1 cycle with<br />

current peak<br />

t<br />

S6 cycle<br />

t<br />

S6 cycle with<br />

current peak<br />

t