Terminal strip to connect the Ballast resistor<br />

The power supply is supplied from factory with a wire jumper between terminals<br />

Ri and L+. This configuration of the power supply means that it<br />

comes from the factory with its internal Ballast resistor.<br />

However, if with this internal resistor it is not possible to dissipate enough<br />

power (e.g. when braking), the configuration must be modified so the<br />

power supply can work with an external ballast resistor capable of dissipating<br />

that energy. Remove the wire between terminals Ri and L+ and<br />

connect the proper external resistor between terminals Re and L+. See<br />

the diagram in the figure.<br />

Removing the jumper between Ri and L+ and not connecting an external<br />

ballast resistor generates error code E215 or E304 on the display. On PS-<br />

25B4 power supplies, the power bus will not be charged.<br />

Here is a graphic representation of the two possible configurations:<br />

Configuration for connecting the<br />

internal Ballast resistor<br />

PS-25B4<br />

PS-65A<br />

R.int<br />

L-<br />

CONTROL<br />

L+<br />

F. H2/9<br />

Ballast resistor connection configurations.<br />

Configuration for connecting the<br />

external Ballast resistor<br />

R.ext<br />

ER+TH-X/X<br />

ER+TH-18/X+FAN<br />

Ri Re L+ Ri Re L+<br />

PS-25B4<br />

PS-65A<br />

R.int<br />

The following table shows the values for gap, tightening torque (wire entry<br />

holes) and other data regarding the screw-on terminals of the ballast<br />

resistor according to power supply model:<br />

T. H2/9 Technical data of the connection terminals of the ballast resistor.<br />

Connector data PS-25B4 PS-65A<br />

Gap (mm) 10.16 -<br />

Min/max tightening torque (Nm) 1.2/1.5 2/2.3<br />

Screw thread M4 M5<br />

Min./max. section (mm²) 0.5/16 0.5/25<br />

Rated current In (A)<br />

Wire data<br />

76 76<br />

Length to strip (mm) 10 16<br />

These power supply carry a protection against over-temperature which<br />

triggers error E301 on the display and stops its operation when reaching<br />

105 °C (221 °F).<br />

L-<br />

CONTROL<br />

Power supplies<br />

L+<br />

POWER SUPPLIES<br />

Non-regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!