Auxiliary modules<br />

4.<br />

AUXILIARY MODULES<br />

Chokes<br />

204<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

192<br />

MANDATORY. The use of these chokes is a must for the proper operation<br />

of the XPS regenerative power supplies. The length of the cable joining<br />

the choke with the power supply must never exceed 2 meters.<br />

Chapter 6. POWER LINE CONNECTION shows the strict rules that<br />

must be followed to properly install the chokes. Chapter 11. DIMEN-<br />

SIONS of this manual shows the dimensions.<br />

RPS chokes. Technical data<br />

F. H4/3<br />

RPS chokes.<br />

RPS-75-3 choke<br />

RPS-45 choke<br />

RPS-20 choke<br />

Three-phase chokes<br />

T. H4/4 Technical data.<br />

CHOKE RPS-20 RPS-45 RPS-75-3<br />

Inductance (8 kHz ) 0.90 mH 0.40 mH 0,175 mH<br />

Rated current 32 A 72 A 120 A<br />

Max current 50 A 125 A 180 A<br />

Min. cable section 10 mm² 35 mm² 70 mm²<br />

Approx. mass kg / lb 12.7 / 28.0 20.4 / 44.9 36.0 / 79.3<br />

Operating ambient temp. 0 °C to 60 °C (32 °F to 140 °F)<br />

Storage temperature - 20 °C to 60 °C (- 4 °F to 140 °F)<br />

Relative humidity < 90 % non condensing at 45 °C (113 °F)<br />

Operating vibration 0.5 G<br />

Shipping vibration 2 G<br />

Sealing IP 20<br />

MANDATORY. Installing chokes is an absolute must when using RPS regenerative<br />

regulated power supplies and they must always be installed<br />

between the power supply and the mains filter. The length of the cable<br />

joining each choke with the power supply must never exceed 2 meters<br />

and must be shielded.<br />

Chapter 6. POWER LINE CONNECTION shows the strict rules that<br />

must be followed to properly install the chokes. Chapter 11. DIMEN-<br />

SIONS of this manual shows the dimensions.