28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

POWER LINE<br />

CONNECTION<br />

6.1 Mains connection<br />

6<br />

The FAGOR DDS modular servo drive system is designed to be connected<br />

to TN type three-phase mains with values within the voltage range between<br />

400-10% and 460+10% V AC and a mains frequency of 50/60 Hz.<br />

Connecting it to a different voltage range requires the use of transformers<br />

or autotransformers.<br />

The connection may vary depending on the type of mains and electromagnetic<br />

compatibility required by the machine.<br />

Certain mandatory protection devices must be added to the mains lines.<br />

Others are optional.<br />

PROPER INSTALLATION<br />

MAINS CONNECTION (TN TYPE)<br />

OTHER<br />

UNITS<br />

R S T<br />

DIFFERENTIAL<br />

BREAKER<br />

TRANSFORMER<br />

OR<br />

AUTOTRANSFORMER<br />

MAINS<br />

FILTER<br />

L1 L2 L3<br />

3X400-460 V AC<br />

DDS CONNECTION<br />

- S1<br />

MAIN SWITCH<br />

FUSES<br />

(required)<br />

- KM1<br />

POWER<br />

SWITCH<br />

OTHER<br />

UNITS<br />

- KM2<br />

POWER<br />

SWITCH<br />

F. H6/1<br />

Diagram to connect the DDS system to mains.<br />

MAINS CONNECTION (TN TYPE)<br />

R S T<br />

DIFFERENTIAL<br />

BREAKER<br />

TRANSFORMER<br />

OR<br />

AUTOTRANSFORMER<br />

MAINS<br />

FILTER<br />

L1 L2 L3<br />

3X400-460 V AC<br />

DDS CONNECTION<br />

- S1<br />

MAIN SWITCH<br />

FUSES<br />

(required)<br />

- KM1<br />

POWER<br />

SWITCH<br />

OTHER<br />

UNITS<br />

Note. The mains filter may be installed either before or after the power<br />

contactor - KM1.<br />

MANDATORY.<br />

Never connect in parallel with the DDS system other elements such as<br />

moors, inductive components, etc. to avoid the risk of poor system performance<br />

when stopping the machine.<br />

Always connect the power supply of other equipment being installed and<br />

run together with the DDS system through a second contactor - KM2 or<br />

through auxiliary contacts of the power (main) contactor - KM1.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

233

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!