28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Compatibility<br />

13.<br />

COMPATIBILITY<br />

Module replacement<br />

384<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

380<br />

13.3 Module replacement<br />

13.4 VECON board<br />

13.5 VECON-2 board<br />

Replacing 380 V AC module with a new 460 V AC module involves:<br />

Drive MSC 12A or later.<br />

Auxiliary power supply APS 24 PF 05A and later.<br />

Capacitor module CM 1.60 (version [CAP 00A] [VAR 02A] and later).<br />

NOTE. It may be incorporated into any servo drive system regardless of<br />

its power supply.<br />

Power supply PS-A.<br />

NOTE. A PS- power supply is required if the system includes an element<br />

that must work at a mains voltage of 380 V AC like an “MSC 11A”<br />

drive or an APS 24 “PF 04A” power supply or a capacitor module CM 60<br />

“00A”. A PS- is a PS-A. A factory limited to work at 380 V AC. It<br />

will admit a mains voltage limited to 380 V AC.<br />

NOTE. If the system includes only “MSC 12A” drives, there is no compatibility<br />

problem. It will admit a mains voltage between 380 and 460 V AC.<br />

Power supply PS-25B.<br />

NOTE. A PS-25B3 power supply is required to work at 380 V AC if the<br />

system includes an element that must work at a mains voltage of 380 V<br />

AC like an “MSC 11A” drive or a capacitor module CM 60 “00A”.<br />

Compact drives.<br />

NOTE. The compact drives (version MSC 05A and later) are designed to<br />

also run at 380-460 V AC; a PS-25B4 power supply must be installed;<br />

they have no compatibility problems with previous equipment.<br />

The compatibility between this board and the software versions is:<br />

Version of the VECON board Software version<br />

VEC 03A and older 03.07 to 03.23<br />

VEC 04A and later<br />

03.24 and later<br />

04.08 and later<br />

NOTE. It is not possible to regulate with direct feedback when using a<br />

drive with software versions 04.xx and 05.xx and an asynchronous motor<br />

FM7. It is possible with versions 06.xx and later.<br />

This board replaces the VECON board expanding the capacity of the flash<br />

memory and increasing the operating speed of the flash memory and of<br />

the RAM memory.<br />

Version of the VECON-2 board Software version<br />

VEC 01A and later<br />

05.08 and later<br />

06.01 and later<br />

NOTE. Software versions 04.xx and 05.xx of the drive have the same features.<br />

Their only difference consists in that they are supported by different<br />

hardware platforms because they have only VECON and VECON-2<br />

boards respectively.<br />

NOTE. It is possible but not recommended to have the same machine<br />

with several units where one controls its motor with a 04.xx version and<br />

hardware with VECON another one that controls its motor with a 05.xx<br />

version and hardware with VECON-2 and a third one that control its motor<br />

with 06.xx version and hardware with VECON-2.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!