i<br />

F. H2/22<br />

Version label of the APS-24.<br />

Observe the PF reference on the versions label.<br />

Depending on this reference, it will be possible to connect<br />

the APS-24 or not to the DC bus of the DDS system<br />

with XPS regenerative power supplies.<br />

INFORMATION. It will not be necessary to install external protection fuses<br />

in these power lines of the auxiliary power supply. They are already integrated<br />

in the power supply itself.<br />

Remember that the purpose of connecting an auxiliary power supply APS-<br />

24 to the DC bus of a DDS system is to ensure the supply to all the control<br />

circuits of the power supply and of the drive modules connected to the DC<br />

bus in case of a mains power outage in the auxiliary power supply ensuring<br />

a controlled stop of the moving axes instead of braking out of control by friction.<br />

Bear in mind that although XPS power supplies come with an internal auxiliary<br />

power supply offering 3 outputs with 24V DC and a total of 8 A, 192 W,<br />

this power may not be enough to feed the control circuits of all the modules<br />

connected or other elements (e.g. a fan). That is why it may be necessary to<br />

also install an APS-24 auxiliary power supply to guarantee all the power<br />

needed.<br />

The APS-24 auxiliary power supply offers 3 outputs with 24 V DC and a total<br />

of 10 A, 240 W.<br />

For further information about the auxiliary module APS-24, see chapter 4.<br />

AUXILIARY MODULES in this manual.<br />

Choke connection terminals<br />

Regenerative power supplies XPS-25 and XPS-65 offer the connection terminals<br />

labeled CH1 and CH2 at the bottom of the module for connecting the<br />

choke. See figure F. H2/17 and figure F. H2/18.<br />

This inductive device is a must to limit the current circulating from the power<br />

bus to mains.<br />

FAGOR supplies the choke XPS-25 and choke XPS-65-A for this application.<br />

Use cables with the maximum section allowed 16 and 50 mm² y and shorter<br />

than 2 meters (6 feet). They do not have to be shielded.<br />

T. H2/18 Data of the feed-through terminal blocks for connecting the choke.<br />

Connector data CHOKE XPS-25 CHOKE XPS-65-A<br />

Min/max tightening torque (N·m) 2.0/2.3 6.0/8.0<br />

Screw thread M5 M6<br />

Min./max. section (mm²) 0.5/16 16/50<br />

Rated current In (A) 76 150<br />

WARNING. The choke is an absolute must for the operation of a regenerative<br />

power supply. Installing the coil with an inductance other than the<br />

choke recommended in table T. H2/14 may cause severe damage to the<br />

unit.<br />

Power supplies<br />

POWER SUPPLIES<br />

Regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

61