Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

56<br />

Regenerative power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

XPS-65. Connector description<br />

The regenerative power supply XPS-65 has the following connectors:<br />

X2.<br />

X1.<br />

X4.<br />

X5.<br />

X6.<br />

CH1 CH2<br />

X3.<br />

4.<br />

3.<br />

Ri Re L+<br />

L1 L2 L3<br />

CH1 CH2<br />

F. H2/18<br />

Connectors of the PS-65 power supply.<br />

1. Power connector for the three-phase mains.<br />

2. Power connector for the external Ballast resistor connection.<br />

3. Ground connection for the mains cable.<br />

4. Power Bus supplying power to the drive modules through metal bars.<br />

5. Connectors for the choke of the XPS-65.<br />

X1. Connector for inter-module communication.<br />

X2. Connector for the basic control signals.<br />

X3. Input connector supplying from mains to the auxiliary power supply integrated into the module. The<br />

mains power is received through it. It admits a voltage between 400 and 460 V AC.<br />

X4. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

X5. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

X6. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

2.<br />

XPS 65<br />

5.<br />

1.<br />

CAUTION. AC touch current<br />

greater 3.5 mA. Install ground wire<br />