XPS modules<br />

Technical data<br />

T. H2/14 Technical characteristics.<br />

XPS-25 XPS-65<br />

Power supply (Vmains)<br />

Three-phase 50/60 Hz, with a voltage range<br />

between 400-10% and 460+10% V AC<br />

Mains power consumption (400 V AC) 36 Arms 95 Arms<br />

Maximum connection cable section 16 mm² 50 mm²<br />

Power bus voltage VbusNom 565 V DC / 650 V DC<br />

Rated (peak) output current 1 45 A (135 A, 1 s) 120 A (120 A, 1 s)<br />

Rated (peak) output power 25 kW (55 kW, 1 s) 65 kW (108 kW, 1 s)<br />

Regenerating circuit ON/OFF voltage V mains · 1.414 + 150 V<br />

Rated regenerated current (returned to mains) 1<br />

(400 V AC)<br />

28 Arms 72 Arms<br />

Rated regenerated power (returned to mains) 20 kW 54 kW<br />

Isolated choke CHOKE XPS-25 CHOKE XPS-65-A<br />

Choke-drive cable (max length: 2 m) 16 mm² 50 mm²<br />

Output voltage of the auxiliary power supply 24 V DC ± 5%<br />

Maximum current supplied 8 A at 24 V (192 W)<br />

Mains consumption to generate 24 V DC 0.72 A (400 V AC); 0.63 A (460 V AC)<br />

Internal Ballast resistance (power) 1 18 (520 W) 9 (1800 W)<br />

Energy pulse to be dissipated 18 kW (0.6 s) kW<br />

Ballast circuit ON/OFF 765 V DC / 755 V DC<br />

Minimum external Ballast resistance 18 9 <br />

Filter capacity 1175 µF, 900 V DC 2115 µF, 900 V DC<br />

Energy stored in the capacitors 0.5 C V²<br />

Maximum “SYSTEM OK” contact voltage 125 V AC, 150 V DC<br />

Maximum “SYSTEM OK” contact voltage 1 A<br />

Width 194 mm (7.64 in) 234 mm (9.21 in)<br />

Approx. mass 14 kg (31 lb) 19 kg (42 lb)<br />

Power dissipated at maximum load 180 W 350 W<br />

1 See derating curves in case of high temperatures.<br />

T. H2/15 Ambient conditions and other characteristics.<br />

XPS-25 XPS-65<br />

Ambient temperature 1 5°C / 45°C (41°F / 113°F)<br />

Storage temperature - 20°C / 60°C (- 4°F / 140°F)<br />

Maximum humidity < 90% ( non condensing at 45°C / 113°F )<br />

Maximum altitude without loss of features 1000 m (3281 ft) above sea level<br />

Operating vibration 0.5 G<br />

Shipping vibration 2 G<br />

Sealing IP 20<br />

Protections<br />

1 See derating curves in case of high temperatures.<br />

Over-voltage, over-current, hardware error,<br />

ambient temperature.<br />

Power supplies<br />

POWER SUPPLIES<br />

Regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />