Installation<br />

8.<br />

INSTALLATION<br />

Connection between modules<br />

312<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

280<br />

Joining the chassis between modules<br />

The chassis of the modules must be connected to each other through the<br />

terminal on top of each module. To do this, the third plate and the washers<br />

and nuts supplied with each module.<br />

F. H8/9<br />

Joining the chassis between modules.<br />

TOP VIEW:<br />

PLATE ROTATION<br />

The tightening torque must be between 2.32.8 Nm.<br />

Connecting these terminals by means of metal plates offers mechanical rigidity;<br />

but it does not guarantee proper ground connection of each module.<br />

To replace a drive module in case of a failure or remove it from the DDS<br />

system for inspection, follow these steps to “free” it from the other modules.<br />

A. Loosen the screw and the nut of the affected module.<br />

B. Loosen the nut of the adjacent drive on each side that joins it to the<br />

affected drive.<br />

C. Rotate the plate of the affected drive and that of the one to its left, see<br />

figure F. H8/9.<br />

After these steps, the drive will be totally free from the rest of the drives that<br />

were joined by the plate.<br />

All the cables connecting it to the rest of the modules must also be removed.