10.4 SCD compact drive with FM7 asynchronous spindle motor<br />

POWER MAINS<br />

May be connected<br />

in any order.<br />

400/460 V AC<br />

F. H10/4<br />

+24 V DC<br />

0 V.<br />

TO THE<br />

ELECTRICAL<br />

MANEUVER<br />

MPC- 4x...<br />

AUXILIARY POWER SUPPLY<br />

May be connected<br />

in any order.<br />

2 x 400-460 V AC<br />

Programmable<br />

Inputs (24 V DC)<br />

Programmable<br />

Outputs<br />

(24 V - 1 A)<br />

OUT<br />

IN<br />

ERROR RESET<br />

DRIVE ENABLE<br />

SPEED ENABLE<br />

DR. O.K.<br />

L1<br />

L2<br />

110 mA maximum<br />

PROG. OUT<br />

IN-1<br />

IN-2<br />

IN-3<br />

IN-4<br />

OUT-1<br />

OUT-2<br />

OUT-3<br />

OUT-4<br />

(-)<br />

(+)<br />

(-)<br />

(+)<br />

-15 V DC<br />

+15 V DC<br />

Analog Output 2<br />

Analog Output 1<br />

(-)<br />

Analog Input 2<br />

Analog Input 1<br />

(+)<br />

(-)<br />

(+)<br />

2.5 A<br />

450 V AC<br />

2.5 mm²<br />

Tk<br />

Tk<br />

External Ballast<br />

ER+TH-24/750<br />

EXTERNAL<br />

THERMOSTAT<br />

200°C<br />

Digital Spindle Compact Drive<br />

SCD 1.25-A ...<br />

0<br />

X1<br />

1<br />

2<br />

3<br />

1 A<br />

(T) Fuses<br />

X2<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

12<br />

13<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

10<br />

11<br />

R<br />

S<br />

T<br />

SL1<br />

4<br />

X6-DIGITAL I/Os<br />

OV2<br />

OV1<br />

Ri<br />

Re<br />

L+<br />

L-<br />

NODE<br />

SELECT<br />

8<br />

OUT<br />

IN<br />

X7-ANALOG I/Os<br />

3<br />

(Phoenix,<br />

7.62 mm)<br />

(Phoenix, 5.08 mm)<br />

OP5<br />

-15 V<br />

+15 V<br />

X1<br />

Internal<br />

use.<br />

X2<br />

A1 Board<br />

IP10<br />

IP11<br />

IP12<br />

IP13<br />

OP10<br />

OP11<br />

OP12<br />

OP13<br />

P2<br />

IV2<br />

P1<br />

IV1<br />

OP2<br />

OP4<br />

OP1<br />

OP3<br />

1<br />

1<br />

10<br />

11<br />

15<br />

26<br />

19<br />

X6-DIGITAL I/Os<br />

X7-ANALOG I/Os<br />

(Sub-D, M9)<br />

X3<br />

1<br />

5<br />

(HD,<br />

Sub-D,<br />

M15)<br />

X4<br />

6<br />

9<br />

9<br />

1<br />

(HD,<br />

Sub-D,<br />

F26)<br />

1<br />

13<br />

P2<br />

1<br />

11<br />

X5<br />

(Phoenix, 3.5 mm)<br />

P1<br />

Encoder simulator<br />

option<br />

A<br />

/A<br />

B<br />

/B<br />

Io<br />

/Io<br />

Reserv.<br />

Reserv.<br />

0 V<br />

Ready Made Cable<br />

EEC- FM7S 3/5/10/15/20/25/30/35/40/45/50<br />

Length in meters;<br />

including connectors<br />

MLR-12<br />

Connection of an SCD compact drive with an FM7 asynchronous spindle motor with TTL encoder.<br />

1<br />

5<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

11<br />

(HD,Sub-D,F15)<br />

GND<br />

COS<br />

REFCOS<br />

SIN<br />

REFSIN<br />

(Phoenix, 3.5 mm)<br />

+5 V<br />

(HD, Sub-D, M26)<br />

MPC- 4x...<br />

Cable without connectors<br />

Serial Line<br />

Interface<br />

Board<br />

RxD<br />

TxD<br />

24<br />

25<br />

1<br />

10<br />

2<br />

11<br />

TEMP 21<br />

TEMP 22<br />

CHASSIS<br />

26<br />

2<br />

3<br />

X4<br />

3<br />

Io<br />

REF Io<br />

12<br />

U<br />

V<br />

W<br />

X5<br />

X3<br />

NC X7<br />

Relay<br />

AS1<br />

AS2<br />

(Phoenix,<br />

5.08 mm)<br />

Cable 3x2x0.14+4x0.14+2x0.5<br />

Cable 4x2x0.142x0.5<br />

Green<br />

Yellow<br />

Blue<br />

Pink<br />

Grey<br />

Brown<br />

White<br />

Purple<br />

Black<br />

Red<br />

Black<br />

Green<br />

Yellow<br />

Blue<br />

Purple<br />

Black<br />

Brown<br />

White<br />

Grey<br />

X3<br />

400 V AC<br />

50/60 Hz<br />

(Sub-D, F9)<br />

Connection diagram of an SCD<br />

compact drive with an FM7 asynchronous<br />

spindle motor that has<br />

encoder feedback.<br />

Ready made cable to 8055/55i CNC,<br />

SEC-HD 1/3/5/10/15/20/25/30/35<br />

Length in meters; including connectors<br />

L2<br />

L1<br />

L3<br />

(Sub-D, M15)<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

U1<br />

V1<br />

W1<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

11<br />

11 THSA<br />

12 THSB<br />

10<br />

SS (shield)<br />

Yellow-Green<br />

2<br />

3<br />

+5 V<br />

0V<br />

PA<br />

*PA<br />

PB<br />

*PB<br />

PC<br />

*PC<br />

M<br />

3<br />

RxD<br />

TxD<br />

(Sub-D, F9)<br />

ENCODER TTL<br />

-t°<br />

6<br />

9<br />

Connection diagrams<br />

(HD,Sub-D,F15)<br />

15<br />

11<br />

5<br />

1<br />

CNC 8055/55i<br />

X2<br />

NTC<br />

Motor ground<br />

screw<br />

1<br />

5<br />

Front View<br />

12 11 10 9<br />

8 7 6 5<br />

4 3 2 1<br />

Note that phases L1 & L2 are swapped<br />

for proper air flow and motor turning directions<br />

indicated on the outside label<br />

Z1<br />

Z2<br />

Electric Fan<br />

Z3<br />

Spindle Motor<br />

FM7...S...<br />

PC-Computer<br />

(Sub-D, M9)<br />

CONNECTION DIAGRAMS<br />

SCD compact drive with FM7 asynchronous spindle motor 10.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />