Selection criteria<br />

5.<br />

SELECTING CRITERIA<br />

Selection of the synchronous motor and its associated drive<br />

232<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

210<br />

Summary of the three pre-selections<br />

• Maximum speed equal to or greater than calculated value in RPM motor<br />

• Stall torque equal to or greater than calculate continuous value Mcontin uous<br />

• Motor inertia equal to or greater than inertia J LOAD / k<br />

• Peak torque equal to or greater than calculated value Mmax • Rated torque equal to or greater than calculated RMS value Mrms Drive selection<br />

Once the motor has been selected, check the electrical characteristics table<br />

in the FXM/FKM AC servomotors manual.<br />

There are several drives available for each motor and the peak torque obtained<br />

with each one of them will be different.<br />

A drive has to be chosen whose peak current is greater than the one calculated<br />