The next table shows the signals and other considerations related to each<br />

pin of connector X2:<br />

T. H2/20 Description of the pins of connector X2.<br />

1 Error RESET<br />

System error RESET input<br />

(24 V DC; 4.5-7 mA).<br />

2 N. C. Not connected<br />

0 volts reference for digital inputs.<br />

3 GND<br />

Error RESET (1) and<br />

System Speed Enable (5).<br />

4 N. C. Not connected<br />

5 System Speed Enable<br />

General system speed enable.<br />

(24 V DC; 4.5-7 mA).<br />

6 System OK Contact indicating module status.<br />

It opens in case of failure.<br />

7 System OK<br />

Limit 1 A at 24 V.<br />

X3, X4, X5 and X6 connectors<br />

These connectors belong to the auxiliary power supply integrated into the<br />

main power supplies XPS-25 and XPS-65.<br />

1<br />

3<br />

Phoenix<br />

7.62 mm<br />

1<br />

3<br />

Phoenix<br />

5.08 mm<br />

XPS-25<br />

XPS-65<br />

1<br />

2<br />

3<br />

X4 X5<br />

1<br />

2<br />

3<br />

F. H2/25<br />

Connectors X3, X4, X5 and X6 that belong to the auxiliary power supply<br />

integrated into regenerative power supplies XPS-25 and XPS-65.<br />

Connector X3 receives power from mains. It admits a voltage between 400<br />

and 460 V AC.<br />

This auxiliary power supply generates 24 V DC and its purpose is to feed<br />

the control circuits of the module itself. Also, it supplies up to 8 A of this dc<br />

voltage through connectors X4, X5 and X6. These three connectors are<br />

identical and offer greater connecting flexibility.<br />

X3<br />

X6<br />

400-460 VAC<br />

+24 VDC<br />

0 VDC<br />

Power supplies<br />

POWER SUPPLIES<br />

Regenerative power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

63