Deactivation of the Speed Enable input<br />

When the Speed Enable input is set to 0 V DC, the internal velocity command<br />

follows the stop ramp set by parameter and:<br />

Situation 1<br />

The torque is kept active by braking the motor. When it stops, variable<br />

SV5 (S00331) is activated. The motor has stopped in a time period<br />

shorter than the one indicated by parameter GP3 (F00702). The<br />

torque is canceled and the rotor is free.<br />

Situation 2<br />

The torque is kept active by braking the motor. When it stops, variable<br />

SV5 (S00331) is activated. The motor does not stop in a time period<br />

set by parameter GP3 (F00702). The motor stops when its kinetic energy<br />

runs out.<br />

Case 1: Running normally<br />

-Fast motor response-<br />

Case 2: Running improperly<br />

-slow motor response-<br />

AS1-AS2<br />

Velocity<br />

Drive Enable<br />

command<br />

Signal<br />

Speed Enable<br />

Function<br />

SV5:<br />

nfeedback