4.2 Chokes<br />

The chokes (inductances or coils) are used with regenerative power supplies<br />

(XPS-25 and XPS-65) and regenerative regulated power supplies<br />

(RPS-80, RPS-75, RPS-45 and RPS-20).<br />

When returning power to mains, the impedance of mains for the outgoing<br />

currents is very low. Hence, the up ramps of this current must be limited<br />

with a choke.<br />

These three-phase chokes for XPS and RPS power supplies must be<br />

connected to the power line input.<br />

On the XPS power supplies, the choke must be connected to power terminals<br />

CH1 and CH2 located at the bottom of the module.<br />

RPS power supplies do not have connection terminals at the bottom of<br />

the module like at XPS power supplies; therefore, it must be connected to<br />

the power line between the MAINS FILTER A and the RPS power<br />

supply itself. See diagrams in the corresponding chapter of this manual.<br />

The internal switching mechanism of these power supplies generates a<br />

regenerative current to mains already filtered by this choke.<br />

FAGOR provides the XPS-25 and XPS-65-A chokes that must necessarily<br />

go with the corresponding XPS power supplies and the RPS-75-3, RPS-45<br />

and RPS-20 chokes that must go with RPS power supplies.<br />

XPS chokes. Technical data<br />

XPS-25 CHOKE<br />

F. H4/2<br />

XPS CHOKES.<br />

XPS-65 CHOKE<br />

Discontinued<br />

T. H4/3 Technical data.<br />

CHOKE XPS-25 XPS-65<br />

XPS-65-A CHOKE<br />

New<br />

DISCONTINUED<br />

Auxiliary modules<br />

XPS-65-A<br />

NEW<br />

Inductance (10 kHz) 0.350 mH 0.175 mH 0.250 mH<br />

Rated current 50 A 120 A 120 A<br />

Peak current 100 A 180 A 185 A<br />

Max. terminal section 10 mm² 50 mm² 70 mm²<br />

Approximate mass kg (lb) 8.0 (17.6) 22.5 (49.3) 36.0 (79.3)<br />

Operating amb.temperature 5°C to 45°C (41°F to 113°F)<br />

Storage temperature - 20°C to + 60°C (- 4°F to 140°F)<br />

Relative humidity 80 % max.<br />

Operating vibration 0.5 G<br />

Shipping vibration 2 G<br />

Sealing IP 20<br />

AUXILIARY MODULES<br />

Chokes 4.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

191