28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Auxiliary modules<br />

4.<br />

AUXILIARY MODULES<br />

External Ballast resistors<br />

204<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

198<br />

Use the attached table to select the Ballast resistor for your compact drive<br />

module when applicable with enough rms power to dissipate the energy<br />

generated while braking.<br />

T. H4/9 Possible braking resistors to be installed on compact drive modules.<br />

Required Ohm values.<br />

ACD 1.15 43 300 W Internal R.<br />

CMC 1.15 43 300 W Internal R.<br />

SCD 1.15 43 300 W<br />

Internal R. or external ER+TH-43/350<br />

(with external thermostat)<br />

ACD 1.25 24 250 W 24550 W *<br />

CMC 1.25 24 250 W 24550 W *<br />

SCD 1.25 24 650 W 24 750 W * with external thermostat<br />

SCD 1.25...NR 24 950 W ER+TH-24/1100<br />

ACD 2.35 18 450 W 18900 W *<br />

CMC 2.35 18 450 W 18900 W *<br />

SCD 2.35 18 1.3 kW 18 1800 W * with internal thermostat<br />

SCD 2.35...NR 18 <br />

2.0 kW ER+TH-18/2200<br />

2.0 kW ER+TH-18/1000+FAN<br />

3.0 kW ER+TH-18/1500+FAN<br />

4.0 kW ER+TH-18/2000+FAN<br />

ACD 2.50 18 450 W 18900 W *<br />

CMC 2.50 18 450 W 18 900W *<br />

SCD 2.50 18 1.3 kW 18 1800 W * with internal thermostat<br />

SCD 2.50...NR 18 <br />

2.0 kW ER+TH-18/2200<br />

2.0 kW ER+TH-18/1000+FAN<br />

3.0 kW ER+TH-18/1500+FAN<br />

4.0 kW ER+TH-18/2000+FAN<br />

SCD 2.75 18 3.0 kW ER+TH-18/1500+FAN *<br />

SCD 2.75...NR 18 4.0 kW ER+TH-18/2000+FAN<br />

* FAGOR supplies the resistors indicated with an asterisk (see shaded<br />

rows) as accessories with the unit. The rest of them are supplied only<br />

upon request.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!