Selection criteria<br />

5.<br />

SELECTING CRITERIA<br />

Power supply selection<br />

232<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

218<br />

5.4 Power supply selection<br />

Calculation of the power required from the power supply by the synchronous servo motors<br />

Initially, considering the mechanical power provided by the motors:<br />

T. H5/5 Power supply selection depending on the mechanical power output of the motor.<br />

SYNCHRONOUS FXM & FKM<br />

Power (characteristics table)<br />

GROUP I<br />

0 to 2 kW<br />

Synchronous<br />

GROUP II<br />

0 to 8.5 kW<br />

Synchronous<br />

GROUP III<br />

8.5 to 27 kW<br />

Synchronous<br />

Synchronous<br />

motors per group<br />

Axes Pcal n nN Pa<br />

1<br />

2<br />

3<br />

1<br />

n : Max. axis speed in the application (rpm)<br />

nN: Motor rated speed (rpm)<br />

Pa= Pcal·1.17· [n/nN] : Axis power (kW)<br />

kW rpm rpm kW<br />

Sum of GROUP I: * Ki <br />

2 +<br />

3<br />

1<br />

Sum of GROUP II: * Kii <br />

2 +<br />

3<br />

Sum of GROUP III: * Kiii <br />

K factor<br />

1 1<br />

2 0.63<br />

3 0.50<br />

4 0.38<br />

5 0.33<br />

6 0.28<br />

... where:<br />

=<br />

SUM OF POWER: (kW) 1<br />

Pcal: motor power (kW) according to the motor<br />

characteristics table.<br />

1.17: coefficient that stores the efficiency of the<br />

motor (0.9) and that of the drive (0.95).<br />

The servo set is divided in groups depending on<br />

their power by applying to each one a simultaneity<br />

factor Ki, Kii, Kiii.