OPERATION DIAGRAM. PS-65A<br />

EMERG.<br />

STOP<br />

PS-65A<br />

SYSTEM OK<br />

I1 PLC<br />

CNC EMERG.<br />

O1 PLC<br />

-KA1<br />

X+<br />

X-<br />

Y+<br />

Y-<br />

Z+<br />

Z-<br />

OFF<br />

-KM1<br />

EMERGENCY LINE<br />

+24VDC<br />

KA1 KM1<br />

ON KM1<br />

-KA2<br />

SYSTEM<br />

SPEED<br />

ENABLE<br />

-KA3<br />

DRIVE<br />

ENABLES<br />

(See GP9)<br />

ON<br />

Green<br />

KA2 KA2<br />

OFF<br />

Red<br />

DELAY OFF<br />

t seconds<br />

CNC<br />

ENABLE<br />

S<br />

F. H10/10<br />

System with a PS-65A power supply. Diagram of the maneuver.<br />

F. H10/11<br />

General diagram of a DDS system with a PS-65A power supply.<br />

KA1<br />

KA2<br />

CNC<br />

ENABLE<br />

X<br />

CNC<br />

ENABLE<br />

Y<br />

CNC<br />

ENABLE<br />

Z<br />

-KA7 -KA4 -KA5 -KA6<br />

GND ON OFF to SPEED ENABLES<br />

Note. The relay - KA3 uses delayed<br />

deactivation (t seconds) maintaining<br />

the DRIVE ENABLE control signal<br />

active for a few seconds to maintain<br />

motor torque while the vertical axis<br />

holding brake is enabled.<br />

See parameter GP9 in the<br />

“man_dds_soft.pdf” manual<br />

Connection diagrams<br />

BRK<br />

BRAKE<br />

CONTROL<br />

(See GP9)<br />

Note. CNC EMERG. will always be assigned to I1/O1 of the PLC with an 8055/55i CNC. With an 8070<br />

CNC, it may be assigned to any I/O of the PLC. The contacts associated with relays - KA2, - KA3, -<br />

KA4, - KA5, - KA6 and - KA7 are shown inside a circle in figure F. H10/9 and the contactor - KM1 in figure<br />

F. H10/11.<br />

GENERAL DIAGRAM. PS-65A<br />

PE<br />

POWER MAINS<br />

R<br />

S<br />

T<br />

N<br />

- S1<br />

MECHANICAL<br />

MAIN SWITCH<br />

- F3<br />

- F4<br />

- F5<br />

WARNING. When using an isolating transformer, the secondary must be<br />

connected in star and its middle point must be connected to GND.<br />

IT A MUST TO USE FUSES<br />

- Q1<br />

DIFFERENTIAL<br />

BREAKER<br />

TO THE X1 CONNECTOR<br />

APS 24 AUXILIARY<br />

POWER SUPPLY<br />

L2<br />

Note. Observe that having the main key - S1 closed, although the<br />

power contactor - KM1 is open, the external APS-24 auxiliary<br />

power supply remains connected through its connector X1 to feed<br />

the control circuits of the drive.<br />

L1<br />

2x400-460 VAC<br />

MAINS FILTER 130A<br />

L1 L2 L3<br />

TO THE POWER CONNECTOR<br />

PS-65A POWER SUPPLY<br />

3x400-460 VAC<br />

- KM1<br />

CONTACTOR<br />

R<br />

S<br />

T<br />

CONNECTION DIAGRAMS<br />

Diagrams with a PS-65A power supply 10.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

339