Drive modules<br />

3.<br />

DRIVE MODULES<br />

Compact drives<br />

188<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

154<br />

50<br />

40<br />

30<br />

20<br />

10<br />

0<br />

I (Arms)<br />

Imax<br />

35 40 45 50 55<br />

Tambient<br />

°C (°F)<br />

60<br />

(95) (104) (113) (122) (131) (140)<br />

F. H3/107<br />

Current derating on “SCD 2.75” drives for fc = 8 kHz.<br />

Power derating<br />

SCD 2.75<br />

Tª ambient Imax.<br />

°C °F Arms<br />

35 95 39.0<br />

40 104 39.0<br />

45 113 39.0<br />

50 122 37.7<br />

55 131 33.5<br />

60 140 29.2<br />

The following graph shows the variation suffered by the output rated power<br />

of the compact drive (for all its models) depending on the installation altitude<br />

over sea level.<br />

1.2<br />

1.0<br />

0.8<br />

0.6<br />

0.4<br />

Multiplying factor<br />

(non-dimensional)<br />

0.2<br />

0.0<br />

0 1000 2000 3000 4000<br />

Altitude (m)<br />

5000<br />

Output rated power ratio<br />

Altitude Factor<br />

meters non-dimensional<br />

0 1.00<br />

1000 1.00<br />

2000 0.82<br />

3000 0.71<br />

4000 0.65<br />

5000 0.62<br />

F. H3/108<br />

Derating of rated output power depending on the above-sea-level altitude<br />

of the installation.