PS-25B4<br />

Model currently in the catalog<br />

NOTE. This is the current model with three micro-switches to configure<br />

the selection of the Ballast resistor installed.<br />

The non-regenerative power supply PS-25B4 has three switches on the<br />

front and next to connector X1 (see figure) for selecting the external Ballast<br />

resistor. If you have a model like this one, refer to the attached table<br />

to select the right resistor model according to the setting of the switches<br />

that enables the “I²t” protection. Remember that selecting the internal resistor<br />

or having the RM-15 module means disabling the “I²t” protection because<br />

they both include their own thermostat for their own protection.<br />

T. H2/7 Layout of the ballast resistor selector switches<br />

S3<br />

S2<br />

S1<br />

ON<br />

S3 S2 S1 RESISTOR<br />

OFF OFF OFF Internal<br />

OFF OFF ON ER+TH-18/1100<br />

OFF ON OFF ER+TH-18/1000+FAN<br />

OFF ON ON ER+TH-18/1800<br />

ON OFF OFF ER+TH-18/2200<br />

ON ON OFF RM-15 (discontinued)<br />

DISABLED or<br />

ON OFF ON ER+TH-18/1500+FAN or<br />

ER+TH-18/2000+FAN<br />

DISABLED or<br />

ON ON ON ER+TH-18/1500+FAN or<br />

ER+TH-18/2000+FAN<br />

represents the moving element of the switch in the figure.<br />

Example.<br />

For the switch combination shown in the figure and verified in the table,<br />

the ballast resistor selected would correspond to the ER+TH-18/1800.<br />