28.08.2013 Views

2 - Fagor Automation

2 - Fagor Automation

2 - Fagor Automation

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

68<br />

Regenerative regulated power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

RPS modules<br />

Technical data<br />

T. H2/23 Technical characteristics of the RPS modules.<br />

RPS-80 RPS-75 RPS-45 RPS-20<br />

Power supply (Vmains)<br />

Three-phase 50/60 Hz, with a voltage range<br />

between 400 -10 % and 460 +10 % V AC<br />

Rated mains power consumption 80 kW 76 kW 46 kW 21 kW<br />

Min. power cable section1 70 mm² 70 mm² 35 mm² 10 mm²<br />

Power bus voltage VBUS PROG<br />

600, 625 or 725 V DC. Programmable with VP5<br />

Max. power bus voltage VBUS MAX<br />

775 V DC<br />

Rated (peak, in S6) output current 2<br />

Rated (peak, in S6) output power 3<br />

128 A<br />

(166.5 A)<br />

80 kW<br />

(104 kW)<br />

120 A<br />

(156 A)<br />

75 kW<br />

(97 kW)<br />

72 A<br />

(95 A)<br />

45 kW<br />

(59 kW)<br />

32 A<br />

(41.6 A)<br />

20 kW<br />

(26 kW)<br />

Power dissipated at max. load 1 kW 1 kW 0.7 kW 0.5 kW<br />

Related chokes (three-phase)<br />

choke<br />

RPS-75-3<br />

choke<br />

RPS-75-3<br />

choke<br />

RPS-45<br />

choke<br />

RPS-20<br />

Choke cable - RPS (shielded)<br />

(max. length: 2 m) 1 70 mm² 70 mm² 35 mm² 10 mm²<br />

Power for the module control<br />

circuit (24 V DC)<br />

Three-phase 50/60 Hz, with a voltage range<br />

between 400 -10 % and 460 +10 % V AC<br />

Mains consumption to generate 24 V DC 0.7 A<br />

Output voltage of the auxiliary power 24 V DC ± 5%<br />

Max. current supplied 8 A at 24 V DC (192 W)<br />

Filter capacity 2145 µF, 900 V 825 µF, 900 V 560 µF, 900 V<br />

Energy stored in capacitors 0.5 C V²<br />

Max. “SYSTEM OK”, “LINE CONTACT”<br />

and “AS1-AS2” contact voltage<br />

125 V AC, 150 V DC<br />

Max. current at contacts “SYSTEM OK”,<br />

“LINE CONTACT” and “AS1-AS2”<br />

2 A<br />

Status display 7-segments display<br />

Width (mm/inches) 350 / 13.8 350 / 13.8 311 / 12.2 194 / 7.6<br />

Approx. mass (kg/lb) 20 / 44.1 20 / 44.1 16 / 35.3 10 / 22.0<br />

1 Depending on the rated operating power.<br />

2 For a bus voltage of 625 V.<br />

3 See derating curves in case of high temperatures.<br />

T. H2/24 Ambient conditions and other characteristics of the RPS modules.<br />

RPS-80 RPS-75 RPS-45 RPS-20<br />

Ambient temperature 3 5 °C / 45 °C (41 °F / 113 °F)<br />

Storage temperature - 20 °C / 60 °C (- 4 °F / 140 °F)<br />

Max. humidity < 90 % (non condensing at 45 °C / 113 °F)<br />

Max. altitude without loss of features 1000 m (3281 ft) above sea level<br />

Operating vibration 0.5 G<br />

Shipping vibration 2 G<br />

Sealing IP 20<br />

3 See derating curves in case of high temperatures.