Power supplies<br />

2.<br />

POWER SUPPLIES<br />

94<br />

76<br />

Regenerative regulated power supplies<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />

RPS-45. Connector description<br />

The following figure shows the regenerative regulated power supply RPS-45 and its connector layout:<br />

X3.<br />

X2.<br />

X5.<br />

X6.<br />

X1.<br />

X4.<br />

2.<br />

L1 L2 L3<br />

4.<br />

Top view<br />

CAUTION. AC touch current greater than<br />

3.5 mA. Install ground wire or at least 10<br />

mm² Cu or 16 mm² Al.<br />

L1 L2 L3<br />

F. H2/38<br />

Connectors of the RPS-45 power supply.<br />

1. Power connector for the three-phase mains.<br />

2. Line input connector for synchronism.<br />

3. Ground connection for the mains cable.<br />

4. Power Bus supplying power to the drive modules through metal bars.<br />

X1. Connector of the integrated auxiliary three-phase power supply.<br />

X2. Output connector of the auxiliary 24 V DC power supply integrated into the module.<br />

X3. Connector to be used to open/close the main internal contactor (pins NS1 and NS2) and acknowledge<br />

externally the status of the contactor (LINE CONTACT pins).<br />

X4. Connector to communicate with the modular drives through the internal bus.<br />

X5. Connector for the external acknowledgment of the status of the safety relay.<br />

X6. Connector for the basic control signals.<br />