The next table shows the signals and other considerations related to each<br />

pin of connector X6:<br />

T. H2/37 Description of the pins of connector X6.<br />

1 ERROR RESET<br />

System error RESET input<br />

(24 V DC; 4.5-7 mA).<br />

2 N.C. Not connected<br />

3 GND<br />

4 PWM ENABLE<br />

5<br />

SYSTEM SPEED<br />

ENABLE<br />

0 volts reference for digital inputs.<br />

Error RESET (1) and System Speed Enable (5).<br />

Safety.<br />

Power bus voltage enable input (24 V DC).<br />

General system speed enable.<br />

(24 V DC; 4.5-7 mA).<br />

6 SYSTEM OK Contact indicating module status. It opens in case<br />

of failure. Limit 1 A at 24 V.<br />

7 SYSTEM OK<br />

Power supplies<br />

POWER SUPPLIES<br />

Regenerative regulated power supplies 2.<br />

DDS<br />

HARDWARE<br />

Ref.1307<br />