one hour to <strong>the</strong> next – corresponding to that <strong>the</strong>ir energy exchange can change from zeroto full or from full to zero within 3 hours. They can still regulate <strong>the</strong>ir power within <strong>the</strong>full range <strong>for</strong> shorter periods.For larger wind farms this means that <strong>the</strong> up-regulating of <strong>the</strong> generation is restricted(this is easy to implement), <strong>and</strong> <strong>the</strong> down-regulation of <strong>the</strong> production must be controlled– ei<strong>the</strong>r by reacting in due time be<strong>for</strong>e larger changes in wind energy are expected or byadding compensating power regulation capabilities, e.g. storage units.The customer’s active <strong>and</strong> reactive power exchange, E P i <strong>and</strong> E Q i , will be accounted at <strong>the</strong>actual prices, c p i <strong>and</strong> c Q i : Note, that <strong>the</strong>se amounts can be positive or negative, depending on <strong>the</strong> direction of <strong>the</strong>energy flow <strong>and</strong> if <strong>the</strong> prices are negative.In addition, <strong>the</strong> customer will pay a daily amount, C P E <strong>and</strong> C Q E , relative to <strong>the</strong> dailyenergy flow in both directions, E P d <strong>and</strong> E Q d : where || ||an amount relative to <strong>the</strong> maximum power exchange on daily basis: max max <strong>and</strong> finally a fixed amount, C S , <strong>for</strong> being connected to <strong>the</strong> power system, depending on<strong>the</strong> rated power capacity of <strong>the</strong> connection. These cost elements, C E , C p <strong>and</strong> C S ,correspond to <strong>the</strong> customer’s use of <strong>the</strong> power system.The total daily amount to be accounted is thus: Note, that this amount can become positive or negative – negative means that <strong>the</strong>customer shall pay <strong>the</strong> amount to <strong>the</strong> power system operator <strong>and</strong> positive means that <strong>the</strong>power system operator shall pay <strong>the</strong> amount to <strong>the</strong> customer – corresponding to <strong>the</strong> signof <strong>the</strong> power flow. All values will be recorded on hourly basis as basis <strong>and</strong> documentation<strong>for</strong> <strong>the</strong> billing.3.3 Frequency responseAll power units must be designed to operate properly within a wider frequency range,45..55 Hz. The active power unit’s active power must automatically respond to (larger)deviations (from nominal, f 0 ) of <strong>the</strong> line frequency, f – see Figure 6.Risø International <strong>Energy</strong> Conference 2011 Proceedings Page 182

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!