Table 91 — Alert <strong>and</strong> Alarm Codes<br />

ALARM OR<br />

DESCRIPTION ACTION TAKEN BY CONTROL RESET METHOD<br />

ALERT NUMBER<br />

T048 CktA, Oil Return Not Reliable With Only One Comp Available Circuit shut down Automatic<br />

T049 CktB, Oil Return Not Reliable With Only One Comp Available Circuit shut down Automatic<br />

T051 Circuit A, Compressor 1 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A051 Circuit A, Compressor 1 Stuck On Failure Compressor locked off Manual<br />

T052 Circuit A, Compressor 2 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A052 Circuit A, Compressor 2 Stuck On Failure Compressor locked off Manual<br />

T053 Circuit A, Compressor 3 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A053 Circuit A, Compressor 3 Stuck On Failure Compressor locked off Manual<br />

T054 Circuit B, Compressor 1 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A054 Circuit B, Compressor 1 Stuck On Failure Compressor locked off Manual<br />

T055 Circuit B, Compressor 2 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A055 Circuit B, Compressor 2 Stuck On Failure Compressor locked off Manual<br />

T056 Circuit B, Compressor 3 Failure Compressor locked off (after 3 strikes) Automatic then manual after 3 strikes<br />

A056 Circuit B, Compressor 3 Stuck On Failure Compressor locked off Manual<br />

T057 Circuit A, High Pressure Switch Failure Compressor locked off Automatic then manual<br />

T058 Circuit B, High Pressure Switch Failure Compressor locked off Automatic then manual<br />

T068 Circuit A, Return Gas Thermistor Failure MLV Disabled Automatic<br />

T072 Evap. Discharge Reset Sensor Failure No supply air reset applied Automatic<br />

T073 Outside Air Temperature Thermistor Failure No OAT functions allowed Automatic<br />

T074 Space Temperature Thermistor Failure No SPT functions allowed Automatic<br />

T075 Return Air Thermistor Failure No RAT functions allowed Automatic<br />

T076 Outside Air Relative Humidity Sensor Fail No outside air RH functions allowed Automatic<br />

T077 Space Relative Humidity Sensor Failure No space RH functions allowed Automatic<br />

T078 Return Air Relative Humidity Sensor Fail No return air RH functions allowed Automatic<br />

T082 Space Temperature Offset Sensor Failure No space temperature offset applied Automatic<br />

T090 Circ A Discharge Press Transducer Failure Circuit shut down Automatic<br />

T091 Circ B Discharge Press Transducer Failure Circuit shut down Automatic<br />

T092 Circ A Suction Press Transducer Failure Circuit shut down Automatic<br />

T093 Circ B Suction Press Transducer Failure Circuit shut down Automatic<br />

T110 Circuit A Loss of Charge Circuit locked off Manual<br />

T111 Circuit B Loss of Charge Circuit locked off Manual<br />

P120 Circuit A Low Saturated Suction Temp, Comp Shutdown Circuit staged down Automatic<br />

T120 Circuit A Low Saturated Suction Temperature Alert Circuit shut down Automatic<br />

A120 Circuit A Low Saturated Suction Temperature Alarm Circuit locked off Manual<br />

P121 Circuit B Low Saturated Suction Temp, Comp Shutdown Circuit staged down Automatic<br />

T121 Circuit B Low Saturated Suction Temperature Alert Circuit shut down Automatic<br />

A121 Circuit B Low Saturated Suction Temperature Alarm Circuit locked off Manual<br />

T122 Circuit A High Saturated Suction Temperature Alert Only Manual<br />

T123 Circuit B High Saturated Suction Temperature Alert Only Manual<br />

P126 Circuit A High Head Pressure, Comp Shutdown Circuit stage down Automatic<br />

T126 Circuit A High Head Pressure Alert Circuit shut down Automatic<br />

A126 Circuit A High Head Pressure Alarm Circuit locked off Manual<br />

P127 Circuit B High Head Pressure, Comp Shutdown Circuit stage down Automatic<br />

T127 Circuit B High Head Pressure Alert Circuit shut down Automatic<br />

A127 Circuit B High Head Pressure Alarm Circuit locked off Manual<br />

T128 Digital Scroll High Discharge Temperature Alert Digital compressor A1 shutdown Automatic<br />

A128 Digital Scroll High Discharge Temperature Alarm Digital compressor A1 locked off Manual<br />

A140 Reverse Rotation Detected Stop unit Manual<br />

A150 Unit is in Emergency Stop Unit shut down Manual<br />

A152 Unit Down due to Failure No mechanical cooling available Automatic<br />

T153 Real Time Clock Hardware Failure Unit shut down Automatic<br />

A154 Serial EEPROM Hardware Failure Unit shut down Automatic<br />

T155 Serial EEPROM Storage Failure Error Alert only Automatic<br />

A156 Critical Serial EEPROM Storage Fail Error Unit shut down Automatic<br />

A157 A/D Hardware Failure Unit shut down Automatic<br />

A169 Expansion Valve Control Board Comm Failure Humidimizer control disabled Automatic<br />

T170 Compressor Expansion Board Comm Failure Compressors A3 <strong>and</strong> B3 disabled Automatic<br />

108