ACCSY — Accessory<br />
ACC’Y — Accessory<br />
AN — Analog<br />
APS — Air Pressure Switch<br />
BM — Blower Motor<br />
BR — Blower Relay<br />
C — Compressor Contactor<br />
CB — Compressor Circuit Breaker<br />
CBT — Circuit Breaker, Transformer<br />
CCB — Control Circuit Breaker<br />
CCH — Crankcase Heater<br />
CCN — Carrier Comfort Network®<br />
CCT — Cooling Coil Thermistor<br />
CEM — <strong>Controls</strong> Expansion Module<br />
CM — Combustion Motor<br />
CMR — Compressor Modulation Relay<br />
COMP — Compressor<br />
CR — Control Relay<br />
CSB — Current Sensor Board<br />
CXB — Compressor Expansion Board<br />
DGS — Discharge Gas Sensor<br />
DI — Digital Input<br />
DPT — Discharge Pressure Transducer<br />
DTT — Discharge Temperature Thermistor<br />
DUS — Digital Unloader Solenoid<br />
ECON — Economizer<br />
EQUIP — Equipment<br />
EXB — Economizer Control Board<br />
EXH — Exhaust<br />
EXV — Electronic Expansion Valve<br />
FU — Fuse<br />
GND — Ground<br />
GVR — Gas Valve Relay<br />
HC — Heater Contactor<br />
HIR — Heat Induction Relay<br />
HMV — Humidi-MiZer Valve<br />
ROOFTOP CONTROL BOARD (RXB) — The RXB has<br />
additional inputs <strong>and</strong> outputs required for the control of the<br />
unit. All units have an RXB board. See Fig. 30. The board has<br />
9 inputs <strong>and</strong> 8 outputs. Details can be found in Table 93. The<br />
RXB board is located in the main control box.<br />
ECONOMIZER CONTROL BOARD (EXB) — The EXB<br />
is used on size 075-100 units with optional return/exhaust fan,<br />
optional digital scroll compressor, or accessory humidifier. See<br />
Fig. 30. The board has inputs to sense the return fan cfm <strong>and</strong><br />
supply fan cfm. This board is located in the main control box.<br />
Input <strong>and</strong> output assignments are summarized in Table 94.<br />
STAGED GAS HEAT BOARD (SCB) — When optional<br />
staged gas heat is used, the SCB board is installed <strong>and</strong> controls<br />
additional stages of gas heat. See Fig. 31. The SCB also provides<br />
additional sensors for monitoring of the supply-air <strong>and</strong><br />
limit switch temperatures. This board is located in the main<br />
unit control box. The inputs <strong>and</strong> outputs are summarized in<br />
Table 95.<br />
CONTROL EXPANSION MODULE (CEM) — The optional<br />
CEM is used to provide inputs for dem<strong>and</strong> limiting, remote set<br />
point <strong>and</strong> other optional inputs typically needed for energy<br />
management systems. See Fig. 32. On CCN systems these<br />
inputs can be interfaced to through the CCN communications.<br />
It is located in the main control box. The CEM also has inputs<br />
for accessory relative humidity sensors. This board is also used<br />
on units equipped with optional outdoor air CFM monitoring.<br />
The inputs <strong>and</strong> outputs are summarized in Table 96.<br />
The optional (or accessory) CEM is used to accept inputs<br />
for additional sensors or control sequence switches, including:<br />
• Smoke control mode field switches<br />
• VAV supply air set point reset using an external 4 to<br />
20 mA signal<br />
• Outdoor air CO 2 sensor<br />
• Space, return <strong>and</strong>/or outdoor air relative humidity<br />
sensors<br />
LEGEND FOR FIG. 19-28<br />
HPS — High-Pressure Switch<br />
HS — Hall Effect Sensor<br />
HV — High Voltage<br />
I — Ignitor<br />
IAQ — Indoor Air Quality<br />
IDM — Induced Draft Motor<br />
IFC — Indoor Fan Contactor<br />
IFCB — Indoor Fan Circuit Breaker<br />
IFM — Indoor Fan Motor<br />
IGC — Integrated Gas Controller<br />
LEN — Local Equipment Network<br />
LLS — Liquid Line Solenoid<br />
LON — Local Operating Network<br />
LS — Limit Switch<br />
MBB — Main Base Board<br />
MGV — Main Gas Valve<br />
MLV — Minimum Load Valve<br />
NEC — National Electrical Code<br />
OA — Outdoor Air<br />
OAQ — Outdoor Air Quality<br />
OAT — Outdoor-Air Thermostat<br />
OD — Outdoor<br />
OFC — Outdoor Fan Contactor<br />
OFM — Outdoor Fan Motor<br />
OPT — Option<br />
PE — Power Exhaust<br />
PEC — Power Exhaust Contactor<br />
PECB — Power Exhaust Circuit Breaker<br />
PEM — Power Exhaust Motor<br />
PL — Plug Assembly<br />
PTC — Positive Temperature Coefficient<br />
Power Reference<br />
RA — Return Air<br />
RAT — Return Air Thermistor<br />
RET — Return<br />
RF — Return Fan<br />
127<br />
RS — Rollout Switch<br />
RXB — Rooftop Control Board<br />
SAT — Supply Air Thermistor<br />
SCB — Staged Gas Control Board<br />
SEN — Sensor<br />
SPT — Suction Pressure Transducer<br />
STDU — St<strong>and</strong>ard Tier Display Unit<br />
TB — Terminal Block<br />
TRAN — Transformer<br />
UPC — Unitary Protocol Converter<br />
VAV — Variable Air Volume<br />
VFD — Variable Frequency Drive<br />
Terminal Block<br />
Terminal (Unmarked)<br />
Terminal (Marked)<br />
Splice<br />
Factory Wiring<br />
Field Wiring<br />
To indicate common potential<br />
only, not to represent wiring.<br />
To indicate factory-installed<br />
option or accessory<br />
• IAQ function discrete switch<br />
• Dem<strong>and</strong> limit sequence proportional signals or discrete<br />
switches<br />
The CEM is factory-installed when the outdoor air cfm control<br />
option is installed.<br />
COMPRESSOR EXPANSION BOARD (CXB) — The<br />
CXB is used on size 090 <strong>and</strong> 100 units only to provide additional<br />
compressor outputs <strong>and</strong> CSB inputs. See Table 97.<br />
EXPANSION VALVE CONTROL BOARD (EXV) —<br />
The EXV is used on Humidi-MiZer ® equipped units only. It is<br />
used to provide control of the condenser <strong>and</strong> bypass modulating<br />
valves. See Table 98.<br />
LOW VOLTAGE TERMINAL STRIP — This circuit board<br />
provides a connection point between the major control boards<br />
<strong>and</strong> a majority of the field-installed accessories. See Table 99.<br />
The circuit breakers for the low voltage control transformers,<br />
interface connection for the Carrier Comfort Network ® (CCN)<br />
communication, <strong>and</strong> interface connection for the Local Equipment<br />
Network (LEN) communication are also located on the<br />
low voltage terminal strip.<br />
INTEGRATED GAS CONTROL (IGC) — One IGC is provided<br />
with each bank of gas heat exchangers. One is used on<br />
low heat size 030-050 units. Two are used on high heat size<br />
030-050 units <strong>and</strong> low heat 055-100 units. Three are used on<br />
high heat 055-100 units. The IGC controls the direct spark ignition<br />
system <strong>and</strong> monitors the rollout switch, limit switches,<br />
<strong>and</strong> induced-draft motor Hall Effect switch. The IGC is<br />
equipped with an LED (light-emitting diode) for diagnostics.<br />
See Table 100.<br />
CURRENT SENSOR BOARD (CSB) — This board monitors<br />
the status of the compressor by sensing the current flow to<br />
the compressors <strong>and</strong> then provides digital status signal to the<br />
MBB <strong>and</strong> CXB.