Table 7 — Fan Performance — 48P2,P3,P4,P5055 <strong>and</strong> 50P2,P3055 Units without Discharge Plenum*<br />

AIRFLOW<br />

(cfm)<br />

LEGEND<br />

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)<br />

0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6<br />

Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp<br />

10,000 207 1.04 253 1.50 295 2.03 334 2.66 371 3.41 405 4.26 438 5.20 468 6.20<br />

12,500 235 1.69 276 2.23 312 2.78 346 3.40 379 4.10 410 4.88 440 5.75 469 6.70<br />

15,000 265 2.59 302 3.23 335 3.85 365 4.51 394 5.20 422 5.96 449 6.78 476 7.67<br />

17,500 295 3.78 331 4.52 361 5.24 389 5.97 415 6.71 440 7.48 465 8.30 489 9.17<br />

20,000 327 5.31 360 6.15 388 6.98 414 7.79 439 8.60 462 9.43 485 10.28 507 11.17<br />

22,500 359 7.23 390 8.16 417 9.09 442 10.00 465 10.90 487 11.81 508 12.72 528 13.65<br />

25,000 392 9.59 421 10.60 447 11.62 470 12.64 492 13.64 513 14.63 533 15.62 552 16.62<br />

AIRFLOW<br />

(cfm)<br />

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)<br />

1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2<br />

Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp<br />

10,000 497 7.27 523 8.39 549 9.55 573 10.75 596 11.98 618 13.23 639 14.51 659 15.81<br />

12,500 497 7.73 523 8.83 549 10.00 573 11.22 597 12.49 619 13.81 641 15.16 662 16.55<br />

15,000 501 8.63 526 9.67 550 10.77 574 11.94 597 13.17 619 14.46 641 15.80 662 17.19<br />

17,500 512 10.09 535 11.07 557 12.11 579 13.21 601 14.38 622 15.60 643 16.88 663 18.21<br />

20,000 528 12.09 549 13.06 570 14.07 590 15.12 610 16.24 630 17.40 649 18.62 668 19.89<br />

22,500 548 14.60 567 15.59 587 16.61 605 17.66 624 18.75 642 19.88 660 21.06 678 22.28<br />

25,000 571 17.63 589 18.66 607 19.71 624 20.78 642 21.89 659 23.02 676 24.19 692 25.39<br />

AIRFLOW<br />

(cfm)<br />

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)<br />

3.4 3.6 3.8 4.0<br />

Rpm Bhp Rpm Bhp Rpm Bhp Rpm Bhp<br />

10,000 679 17.13 697 18.46 715 19.81 733 21.17<br />

12,500 682 17.98 702 19.43 721 20.90 739 22.40<br />

15,000 682 18.63 702 20.10 721 21.62 740 23.17<br />

17,500 683 19.60 702 21.04 721 22.53 740 24.06<br />

20,000 687 21.20 706 22.57 724 24.00 742 25.46<br />

22,500 696 23.55 713 24.86 731 26.22 748 27.62<br />

25,000 709 26.62 725 27.91 741 29.22 — —<br />

48/50P3,P5 units only.<br />

Bhp — Brake Horsepower<br />

*If calculating static pressure for a 48 Series unit, be sure to add gas<br />

heat pressure drop from Component Pressure Drop table.<br />

NOTES:<br />

1. Fan performance is based on wet coils <strong>and</strong> clean 2-in. filters.<br />

12<br />

2. See Component Pressure Drop data table before using Fan Performance<br />

tables.<br />

3. Conversion — Bhp to kW:<br />

Kilowatts =<br />

Bhp x .746<br />

Motor efficiency<br />

See Physical Data table for motor efficiency.